{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-8HL32-0AD0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-8HL32-0AD0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-8HL32-0AD0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-8HL32-0AD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-8HL32-0AD0, molded case circuit breaker, 3-pole, 250 A continuous, line protection, 440 kA breaking at 240 V, 86 x 105 x 181 mm.","salesMarkdown":"## Rated continuous current and thermal derating That 250 A holds flat through 50 °C; above that it derates to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. Breaking capacity drops as system voltage rises: 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V. ## Panel fit and auxiliary configuration Three auxiliary switches HQ are built in — that's the HQ designation on the order code, meaning high-capacity auxiliary contacts rated for control circuit switching. The basic switch is order code 3VA2225-8HL32-0AA0; this -0AD0 suffix adds the HQ auxiliaries. ## Operating limits and power loss Maximum power loss is 48 W at rated current — that's heat that stays inside the enclosure, so factor it into your panel thermal budget.","metaTitle":"Siemens 3VA2225-8HL32-0AD0 SENTRON MCCB, 250 A, 3-Pole, 440","metaDescription":"Siemens SENTRON 3VA2225-8HL32-0AD0 molded case circuit breaker, 250 A continuous, 3-pole, 440 kA at 240 V. Current production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"2 500 A","Minimum":"375 A","at 240 V":"440 kA","at 415 V":"330 kA","at 440 V":"330 kA","at 500 V":"220 kA","at 690 V":"52.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"241 A","at 60 °C":"232 A","at 65 °C":"222 A","at 70 °C":"213 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"48 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2225-8HL32-0AA0","Design Of The Auxiliary Switch":"3 auxiliary switches HQ","Design Of The Auxiliary Release":"Without auxiliary release","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"L","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=354339&mlfb=3VA2225-8HL32-0AD0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-8HL32-0AD0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2225-8HL32-0AD0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3VA2225-8HL32-0AD0's depth?","answer":"Listed depth is 86 mm (3.39 in). Width is 105 mm (4.13 in), height is 181 mm (7.13 in)."},{"question":"What is the continuous current rating of this MCCB?","answer":"Rated 250 A continuous at 40 °C ambient. Derates to 213 A at 70 °C — the 70 °C figure governs in hot panels."},{"question":"What breaking capacity does it have at 480 V?","answer":"At 440 V (the closest standard rating to 480 V) it breaks 330 kA. At 500 V it breaks 220 kA. For 480 V systems use the 330 kA figure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-8HL32-0AD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-8HL32-0AD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}