{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5HL32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5HL32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-5HL32-0DA0, molded case circuit breaker, 3-pole, 250 A continuous, 187 kA breaking at 240 V, undervoltage release, line protection design.","salesMarkdown":"## MCCB for line protection with UVR The Siemens SENTRON 3VA2325-5HL32-0DA0 is a 3-pole molded case circuit breaker rated for 250 A continuous current, with a breaking capacity of 187 kA at 240 V AC and 121 kA at 415 V AC. It includes an integrated undervoltage release (UVR) for coordinated shutdown when supply dips below the dropout threshold — essential for motor control centers and process lines where automatic restart after undervoltage is undesirable. The 40 W maximum power loss is manageable in a standard IP enclosure with passive ventilation. ## Breaking performance across voltage levels At 240 V the 3VA2325-5HL32-0DA0 interrupts 187 kA; at 415 V and 440 V it holds 121 kA. At 500 V the rating drops to 75.6 kA, and at 690 V to 7.5 kA. This is a line-protection device, so the high short-circuit ratings at distribution voltages (240–440 V) give selectivity headroom downstream — you can coordinate with smaller branch MCCBs without exceeding the upstream breaker's withstand. Dimensions are 138 mm wide, 248 mm tall, and 110 mm deep. ## Undervoltage release and auxiliary options The undervoltage release (UVR) is factory-installed; no auxiliary switch is fitted. The basic switch variant is order code 3VA2325-5HL32-0AA0, which omits the UVR. If you need a shunt trip or ground-fault monitoring, this variant does not carry them — those are separate order codes in the 3VA2 family.","metaTitle":"Siemens 3VA2325-5HL32-0DA0 SENTRON MCCB, 250 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2325-5HL32-0DA0 molded case circuit breaker, 250 A continuous, 187 kA at 240 V, undervoltage release. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"375 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"40 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-5HL32-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=84752&mlfb=3VA2325-5HL32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA2325-5HL32-0DA0?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability confirmation at quote time."},{"question":"What is the depth of 3VA2325-5HL32-0DA0?","answer":"The listed depth is 110 mm (4.33 in). This fits standard 200 mm deep enclosures with clearance for wiring and arc chutes."},{"question":"What is the width of 3VA2325-5HL32-0DA0?","answer":"The width is 138 mm (5.43 in), matching the SENTRON 3VA3 frame footprint — three 45 mm module spaces on DIN rail."},{"question":"What compliance documentation is available for this MCCB?","answer":"As a Siemens SENTRON product, it carries IEC/EN 60947-2 certification. RoHS and REACH compliance declarations are standard from Siemens for current-production 3VA series breakers."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5HL32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}