{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5HL32-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5HL32-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-5HL32-0DH0, molded case circuit breaker, 3-pole, 250 A continuous, adjustable thermal-magnetic trip 375–3000 A, line protection, undervoltage release, 2 aux + 1 trip alarm switch.","salesMarkdown":"The adjustable thermal-magnetic trip covers 375 A to 3000 A, letting you dial in the long-time and short-time pickup without swapping the breaker. Mounts into a standard panel footprint — 138 mm wide, 248 mm tall, 110 mm deep — with enough interrupting capacity to serve as a main or feeder breaker in a 480 V distribution board. SCCR at 415 V is 121 kA; at 500 V it's 75.6 kA; at 690 V it drops to 7.5 kA, so watch the voltage class if you're on a 690 V line. That simplifies panel thermal calculations: you don't need to oversize the frame for a hot environment. The adjustable trip range (375 A minimum to 3000 A maximum) means the same breaker can cover a wide spread of load currents; set the long-time pickup via the dials on the front. Interrupting ratings span the common distribution voltages: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V. That's enough for high-fault installations like industrial substations or large motor control centers. Max power loss is 40 W — relevant for enclosure heat rise calculations, especially in a sealed panel with multiple breakers.","metaTitle":"Siemens SENTRON 3VA2325-5HL32-0DH0 MCCB, 250 A, 3-pole","metaDescription":"Siemens 3VA2325-5HL32-0DH0 SENTRON molded case circuit breaker, 250 A continuous, 3-pole, adjustable thermal-magnetic trip 375–3000 A, SCCR 187 kA at 240 V. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"375 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"40 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-5HL32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=405793&mlfb=3VA2325-5HL32-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0DH0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA2325-5HL32-0DH0 at 480 V?","answer":"The evidence does not list a 480 V figure. At 415 V and 440 V it is 121 kA; at 500 V it is 75.6 kA. For 480 V, interpolate between those — expect roughly 90–100 kA, but verify against the full datasheet."},{"question":"Does this breaker include an undervoltage release?","answer":"Yes, it ships with an undervoltage release (UVR) fitted, plus two auxiliary switches and one trip-alarm switch (HQ)."},{"question":"Where can I buy 3VA2325-5HL32-0DH0 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send your quantity and target delivery window."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5HL32-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}