{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5HL32-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5HL32-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-5HL32-0KA0, molded case circuit breaker, 3-pole, 250 A continuous, 187 kA at 240 V, line protection with shunt trip release.","salesMarkdown":"## Siemens SENTRON 3VA2325-5HL32-0KA0 — 250 A MCCB with Shunt Trip The Siemens SENTRON 3VA2325-5HL32-0KA0 is a 3-pole molded case circuit breaker rated for 250 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. The integrated shunt trip release (STL) allows remote tripping, so this breaker fits into emergency-stop or load-shedding circuits where a separate undervoltage release is not specified. At 240 V the 3VA2325-5HL32-0KA0 delivers 187 kA breaking capacity; at 415 V and 440 V it holds 121 kA, then drops to 75.6 kA at 500 V and 7.5 kA at 690 V. The minimum breaking capacity is 375 A — below that threshold the internal arc may not extinguish reliably, so the breaker should not be applied on circuits where prospective fault current falls under that floor. Maximum power loss is 37.5 W — within tolerance for a ventilated enclosure; for sealed cabinets, check the internal temperature rise against the 70 °C operating maximum.","metaTitle":"Siemens 3VA2325-5HL32-0KA0 MCCB, 250 A, 3-Pole, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2325-5HL32-0KA0 molded case circuit breaker, 250 A continuous, 3-pole, 187 kA at 240 V. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"375 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-5HL32-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=114772&mlfb=3VA2325-5HL32-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0KA0/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA2325-5HL32-0KA0 and how is it quoted for volume purchases?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2325-5HL32-0KA0's listed depth?","answer":"The listed depth is 110 mm."},{"question":"What is 3VA2325-5HL32-0KA0's listed width?","answer":"The listed width is 138 mm."},{"question":"Will 3VA2325-5HL32-0KA0 drop into a panel specified around 3VA2116-5HL32-0AK0 without rewiring?","answer":"Both are 3-pole SENTRON MCCBs with the same 138 mm width, so the physical footprint matches. However, the 3VA2325-5HL32-0KA0 is a 250 A frame versus the 3VA2116-5HL32-0AK0's lower rating — verify the busbar ampacity and lug size before substitution."},{"question":"What compliance documentation does this brand provide for 3VA2325-5HL32-0KA0?","answer":"Siemens SENTRON MCCBs carry UL, CSA, and IEC certifications per the product standard. RoHS and REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5HL32-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}