{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5HL32-0KC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5HL32-0KC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0KC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0KC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2325-5HL32-0KC0, 3-pole, 250 A rated continuous current, breaking capacity 187 kA at 240 V AC.","salesMarkdown":"## Line protection breaker with shunt trip — 250 A frame The 3-pole frame breaks fault currents up to 187 kA at 240 V AC, 121 kA at 415 V / 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V, covering most industrial service entrance and feeder applications. The basic switch core is order code 3VA2325-5HL32-0AA0 — the -0KC0 suffix adds the shunt trip and aux switch package. The breaker measures 248 mm high × 138 mm wide × 110 mm deep (9.76 × 5.43 × 4.33 inches). That 110 mm depth is the critical dimension for shallow backpanel enclosures — verify gland-plate clearance before committing the cutout.","metaTitle":"Siemens 3VA2325-5HL32-0KC0 SENTRON MCCB, 250 A, 3-Pole, 187","metaDescription":"Siemens 3VA2325-5HL32-0KC0 SENTRON molded case circuit breaker, 250 A continuous, 3-pole, 187 kA breaking at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"375 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-5HL32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=21112&mlfb=3VA2325-5HL32-0KC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HL32-0KC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2325-5HL32-0KC0 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What is the breaking capacity of 3VA2325-5HL32-0KC0 at different voltages?","answer":"187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — covering service entrance and feeder duty across common industrial voltage levels."},{"question":"Does 3VA2325-5HL32-0KC0 include a shunt trip?","answer":"Yes, this variant includes a factory-installed shunt trip release (STL) for remote tripping, plus two HQ auxiliary switches for status indication."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5HL32-0KC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5HL32-0KC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}