{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5HN32-0KL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5HN32-0KL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5HN32-0KL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HN32-0KL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2325-5HN32-0KL0, 3-pole, 250 A continuous, 187 kA interrupting at 240 V AC, line protection design with shunt trip and auxiliary switches.","salesMarkdown":"The Siemens 3VA2325-5HN32-0KL0 is a SENTRON 3VA2-series molded case circuit breaker (MCCB) rated for 250 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed until you exceed that. That 250 A holds at every 5 °C step from 40 up to 70 °C, so it's a straight drop-in for a warm panel without recalculating the thermal curve. Three-pole, line-protection design. Interrupting capacity hits 187 kA at 240 V AC, drops to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V. That 187 kA at 240 V puts it in the high-fault tier for North American 240 V delta or 277/480 V wye panels where the available fault current is stiff. The basic switch core is order code 3VA2325-5HN32-0AA0. Footprint: 138 mm wide, 248 mm tall, 110 mm deep. No special cutout needed if you're replacing an existing 3VA2 frame.","metaTitle":"Siemens 3VA2325-5HN32-0KL0 SENTRON MCCB, 250 A, 3-Pole, 187","metaDescription":"Siemens 3VA2325-5HN32-0KL0 SENTRON molded case circuit breaker, 250 A continuous, 3-pole, 187 kA at 240 V. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"3 000 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-5HN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=495749&mlfb=3VA2325-5HN32-0KL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5HN32-0KL0/alternatives.json"},"ai":{"faq":[{"question":"What are the interrupting ratings for 3VA2325-5HN32-0KL0 at common voltages?","answer":"187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V. The 187 kA at 240 V covers high-fault North American panels; the 121 kA at 415 V suits European 400 V distribution."},{"question":"Does 3VA2325-5HN32-0KL0 require derating at elevated ambient temperatures?","answer":"No derating needed from 40 °C through 70 °C — the 250 A continuous rating holds at every 5 °C step (–). Above 70 °C you would need to consult the thermal derating curve, but for most industrial enclosures that's not a concern."},{"question":"What auxiliary switches and releases come with 3VA2325-5HN32-0KL0?","answer":"It includes two auxiliary switches, one trip alarm switch, one electrical alarm switch (HQ), and a shunt trip (STL) release. No undervoltage release or ground-fault module on this variant. The basic switch core is order code 3VA2325-5HN32-0AA0."},{"question":"How do I get current pricing and availability for 3VA2325-5HN32-0KL0?","answer":"Submit an RFQ with your target quantity and ship window. Availability and current pricing are confirmed at quote time through independent distribution — no published stock count or lead-time figure is maintained on this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5HN32-0KL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5HN32-0KL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}