{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5MN32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5MN32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5MN32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5MN32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-5MN32-0AA0, molded case circuit breaker, 3-pole, 250 A, motor protection design, adjustable trip class 10A/10E/20E, 187 kA at 240 V.","salesMarkdown":"## SENTRON 3VA2325-5MN32-0AA0 — 250 A MCCB for Motor Protection The 3-pole unit carries an insulation voltage rating of 800 V and delivers interrupting capacities of 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — figures that define the fault-clearing capability at the point of installation. The adjustable trip class (Tc CLASS) offers 10A, 10E, and 20E settings, letting the integrator match the thermal overload curve to the motor start profile — 10A for standard starts, 20E for high-inertia loads that need a longer acceleration window. The breaker measures 248 mm high by 138 mm wide by 110 mm deep — a 3-pole frame that fits standard Siemens 3VA switchboard and panelboard footprints. No undervoltage release or shunt trip is fitted on this variant, and the trip indicator is absent, so the panel design must account for external indication if required. The SENTRON series carries the usual Siemens compliance documentation (CE, UL, IEC 60947-2) — the specific certification markings for this order code should be verified against the nameplate for the target jurisdiction.","metaTitle":"Siemens 3VA2325-5MN32-0AA0 SENTRON MCCB, 250 A, 3-Pole, Moto","metaDescription":"Siemens 3VA2325-5MN32-0AA0 SENTRON molded case circuit breaker, 250 A rated current, 3-pole, motor protection design with adjustable trip class. SCCR 187 kA at 240 V. Current produ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"55 000 W","operating power / at AC-3 / at 400 V":"110 000 W","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$635.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569985&mlfb=3VA2325-5MN32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5MN32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA2325-5MN32-0AA0 at different voltages?","answer":"The MCCB delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — these are the maximum fault currents the breaker can safely interrupt at the respective system voltages."},{"question":"How do I get current pricing and availability for 3VA2325-5MN32-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response."},{"question":"What trip classes are available on the 3VA2325-5MN32-0AA0?","answer":"The adjustable trip class offers three settings: 10A, 10E, and 20E, allowing the thermal overload curve to be matched to the motor's starting characteristics."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5MN32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5MN32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}