{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-5MN32-0HB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-5MN32-0HB0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-5MN32-0HB0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5MN32-0HB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA2 IEC frame 400 motor protection circuit breaker, 3-pole, 250A, breaking capacity class M Icu=55kA @ 415V, ETU350M LSI electronic trip, integral shunt trip left 24 V AC/DC.","salesMarkdown":"Siemens 3VA2325-5MN32-0HB0 is an IEC frame 400 motor protection circuit breaker from the 3VA2 series, rated 250 A with a 55 kA interrupting capacity at 415 V AC. The ETU350M LSI electronic trip unit gives you separately adjustable overload (Ir = 100…250 A) and short-circuit (Isd = 3…15 x Ir) protection, plus a fixed instantaneous pickup at Ii = 15 x In. This one ships with a factory-installed shunt trip on the left side, 24 V AC 50/60 Hz or 24–30 V DC, wired for a remote trip signal. Mounts on a 3VA2 frame 400 base, DIN-rail or screw-mount in the panel. The shunt trip sits on the left accessory slot; the right slot accepts a second auxiliary contact block (not included). Wire the shunt trip coil to a 24 V supply — it draws momentarily on trip command, no continuous hold current. The nut keeper kit saves a few minutes during panel build: no loose hardware to drop behind the backplate.","metaTitle":"Siemens 3VA2325-5MN32-0HB0 3VA2 Motor Protection Breaker, 25","metaDescription":"Siemens 3VA2325-5MN32-0HB0 circuit breaker, IEC frame 400, 55kA @ 415V, 3-pole motor protection with ETU350M LSI and shunt trip. Current lifecycle stage. Quoted to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1446058&mlfb=3VA2325-5MN32-0HB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-5MN32-0HB0/alternatives.json"},"ai":{"faq":[{"question":"What does the ETU350M LSI trip unit adjust?","answer":"Overload pickup Ir is adjustable from 100 to 250 A; short-circuit pickup Isd from 3 to 15 times Ir. The instantaneous fixed pickup is 15 times In (250 A). That covers motor starting inrush and lets you coordinate downstream feeder breakers."},{"question":"What voltage does the shunt trip need?","answer":"24 V AC 50/60 Hz or 24–30 V DC. Left-side mounted, factory-installed."},{"question":"Where can I buy 3VA2325-5MN32-0HB0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock figures on this page."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-5MN32-0HB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-5MN32-0HB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}