{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HL32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HL32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-6HL32-0AA0, molded case circuit breaker, 3-pole, 250 A, ETU320 electronic trip unit, 242 kA at 240 V, 187 kA at 415 V.","salesMarkdown":"## 250 A MCCB with ETU320 — selectivity and SCCR headroom The Siemens SENTRON 3VA2325-6HL32-0AA0 is a 3-pole molded case circuit breaker rated 250 A continuous at 40 °C, carrying the same 250 A all the way to 70 °C — no derating needed across the typical panel ambient range. ## Fit and footprint The 3VA2 frame is 138 mm wide, 248 mm tall, and 110 mm deep — a standard MCCB footprint for 250 A class. Front IP40 protection means it's fine in a clean indoor panel; no washdown rating, so keep it out of wet areas.","metaTitle":"Siemens 3VA2325-6HL32-0AA0 SENTRON MCCB, 250 A, 3-Pole, ETU3","metaDescription":"Siemens SENTRON 3VA2325-6HL32-0AA0 molded case circuit breaker, 250 A continuous, 3-pole, ETU320 electronic trip unit. 242 kA at 240 V. Current lifecycle. Sourced to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Courant permanent assigné Iu":"250 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"3 000 A","Adjustable response value current / li min.":"375 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"400 A","Mechanical Service Life (Switching Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"35 x 10 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"20 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=209121&mlfb=3VA2325-6HL32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2325-6HL32-0AA0 drop into a panel specified around 3VA2225-5HN42-0BB0?","answer":"Both are 3-pole 250 A SENTRON MCCBs on the 3VA2 frame, so the mounting footprint and bus-bar centers are the same. The difference is the trip unit — this one carries the ETU320 electronic trip, while the 3VA2225-5HN42-0BB0 uses a different release. If the panel was designed for the thermal-magnetic variant, the ETU320 will fit mechanically but the protection curve and wiring to the trip unit's auxiliary supply (if any) need a quick check against the existing coordination study."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HL32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}