{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HL32-0BC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HL32-0BC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0BC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0BC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-6HL32-0BC0, molded case circuit breaker, 3-pole, 250 A, ETU320 electronic trip unit, line protection, 242 kA interrupting at 240 V.","salesMarkdown":"Three-pole, line-protection version — meaning it's the primary feeder breaker for a distribution panel, motor control center, or heavy industrial load center, not a downstream branch device. ## What the interrupting ratings mean for fit This breaker delivers 242 kA interrupting capacity at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V. If your service entrance or sub-feed has a calculated short-circuit duty of, say, 150 kA at 480 V, this breaker covers it. The 250 A rating holds flat from 40 °C to 50 °C, then steps down: 240 A at 55 °C, 235 A at 60 °C, 230 A at 65 °C, 225 A at 70 °C. Mechanical endurance rated at 15 000 operations.","metaTitle":"Siemens 3VA2325-6HL32-0BC0 SENTRON MCCB, 250 A, 3-Pole, ETU3","metaDescription":"Siemens SENTRON 3VA2325-6HL32-0BC0 molded case circuit breaker, 250 A rated, 3-pole, ETU320 trip unit, 242 kA at 240 V. Active production, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"40 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"240 A","at 60 °C":"235 A","at 65 °C":"230 A","at 70 °C":"225 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"40 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"250 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2325-6HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"250 A","Adjustable response value current / li max.":"3 000 A","Adjustable response value current / li min.":"375 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"400 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"35 x 10","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"20 x 1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=474705&mlfb=3VA2325-6HL32-0BC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0BC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2325-6HL32-0BC0 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source for 3VA2325-6HL32-0BC0?","answer":"The evidence does not list a direct functional second-source or cross-reference for this exact order code. The peer MPNs 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 are catalogued as related but are not drop-in substitutes without verifying footprint, trip curve, and auxiliary wiring — always compare the panel's existing cutout and bus connections before swapping."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"The evidence does not list specific compliance documentation (RoHS, REACH, UL, IEC) for this order code. Standard SENTRON MCCBs typically carry IEC 60947-2 and UL 489 certifications; verify the specific documentation required for your jurisdiction at the time of order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0BC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HL32-0BC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}