{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HL32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HL32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2325-6HL32-0DL0, 250 A continuous, 3-pole, line protection, 242 kA at 240 V.","salesMarkdown":"Its 3-pole design handles line protection duty, with a breaking capacity of 242 kA at 240 V and 187 kA at 415 V, which gives substantial SCCR headroom for most industrial distribution panels. ## Breaking capacity across voltage — what it means for coordination At 240 V the breaker clears 242 kA; at 415 V and 440 V it holds at 187 kA; at 500 V it still manages 121 kA. Only at 690 V does the rating drop to 7.5 kA — a steep roll-off that matters if your panel feeds a 690 V bus. For typical 400 V class distribution the 187 kA figure is well above what most upstream transformers can deliver, so selectivity with downstream devices is straightforward. The breaker measures 138 mm wide, 248 mm high, and 110 mm deep. The depth of 110 mm means it clears most standard enclosure gland plates without interference.","metaTitle":"Siemens 3VA2325-6HL32-0DL0 SENTRON MCCB, 250 A, 3-Pole, 242","metaDescription":"Siemens 3VA2325-6HL32-0DL0 SENTRON molded case circuit breaker, 250 A continuous, 3-pole, 242 kA breaking at 240 V. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"375 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"40 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-6HL32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=380024&mlfb=3VA2325-6HL32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA2325-6HL32-0DL0?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and lead time are confirmed at quote time."},{"question":"What are the key ratings for 3VA2325-6HL32-0DL0?","answer":"Continuous current rating is 250 A (no derating from 40 °C to 70 °C). Breaking capacity is 242 kA at 240 V, 187 kA at 415 V, and 7.5 kA at 690 V. It is a 3-pole line-protection MCCB with undervoltage release and a full auxiliary switch set."},{"question":"Does 3VA2325-6HL32-0DL0 include ground-fault monitoring?","answer":"No, this variant is specified without ground-fault monitoring. It is a line-protection-only breaker."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HL32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}