{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HL32-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HL32-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-6HL32-0HC0, molded case circuit breaker, 3-pole, 250 A, line protection, with shunt trip and 2 auxiliary switches.","salesMarkdown":"The Siemens 3VA2325-6HL32-0HC0 is a SENTRON molded case circuit breaker (MCCB) rated for 250 A continuous current across its full operating temperature range from -25 °C to 70 °C — no derating needed up to that 70 °C ceiling. This is a line-protection device, not a motor-protection breaker, so it's sized for feeder and distribution circuits in industrial panels. Three poles, breaking capacity that steps down from 242 kA at 240 V to 7.5 kA at 690 V, meaning you size it for the available fault current at the point of installation. At 240 V this MCCB interrupts 242 kA — that's utility-grade fault current, typical for a main service entrance or a high-capacity sub-distribution board. ## Integrated auxiliaries and shunt trip The shunt trip lets you remotely open the breaker from a PLC safety output or E-stop circuit without running a separate undervoltage release coil. The two aux switches provide independent status feedback — one for the panel HMI, one for the remote SCADA input. The width at 138 mm (5.43 in) is standard for a 3-pole MCCB in this current class — it occupies one 6-inch-wide slot in a typical distribution panel. Max power loss 37.5 W at full load — plan ventilation if you pack several in a sealed cabinet.","metaTitle":"Siemens 3VA2325-6HL32-0HC0 SENTRON MCCB, 250 A, 3-pole","metaDescription":"Siemens SENTRON 3VA2325-6HL32-0HC0 molded case circuit breaker, 250 A continuous, 3-pole, 242 kA at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"375 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-6HL32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=293127&mlfb=3VA2325-6HL32-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HL32-0HC0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2325-6HL32-0HC0 at different voltages?","answer":"Rated breaking capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V."},{"question":"What auxiliaries are fitted on this MCCB?","answer":"This variant includes a shunt trip (STL) release and two auxiliary switches (HQ design) for remote tripping and status feedback."},{"question":"Where can I buy 3VA2325-6HL32-0HC0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the continuous current rating of 3VA2325-6HL32-0HC0?","answer":"Rated 250 A continuous, with no derating required from -25 °C up to 70 °C ambient."},{"question":"What is the difference between 3VA2325-6HL32-0HC0 and 5SQ2370-2YA05?","answer":"The 5SQ2370-2YA05 is a different product line; this 3VA2325-6HL32-0HC0 is a SENTRON MCCB with shunt trip and dual aux switches. Physical fit and wiring differ — do not assume direct drop-in without comparing the mounting footprint and terminal layout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HL32-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HL32-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}