{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HN32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HN32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HN32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HN32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-6HN32-0DL0, molded case circuit breaker, 250 A, 3-pole, 242 kA at 240 V, line protection, with undervoltage release.","salesMarkdown":"The Siemens SENTRON 3VA2325-6HN32-0DL0 is a 3-pole molded case circuit breaker rated 250 A continuous across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Breaking capacity sits at 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 7.5 kA at 690 V. That SCCR headroom covers most industrial service-entrance and distribution panels where fault current runs high at the lower voltages. It's designed for line protection, so the trip curve and coordination are set for feeder and main breaker duty rather than motor branch-circuit protection. That means you get remote status indication and undervoltage tripping without adding separate accessory modules — one less thing to wire in the panel. The 3-pole block occupies roughly 5.4 inches of rail width; leave clearance above for the arc-chute exhaust and below for the line/load lugs. Power loss is rated at 40 W maximum at full load. That matters for enclosure thermal rise calculations — in a sealed panel, account for that dissipation to keep internal ambient below the 70 °C operating maximum.","metaTitle":"Siemens SENTRON 3VA2325-6HN32-0DL0 MCCB, 250 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2325-6HN32-0DL0 molded case circuit breaker, 250 A continuous, 3-pole, 242 kA breaking at 240 V. Active production. Available to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"3 000 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"40 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-6HN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=73235&mlfb=3VA2325-6HN32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HN32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2325-6HN32-0DL0 at different voltages?","answer":"Breaking capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V. The high interrupt rating at the lower voltages suits it for main breaker duty in high-fault-current installations."},{"question":"Does the 3VA2325-6HN32-0DL0 come with an undervoltage release?","answer":"Yes, it includes an undervoltage release (UVR) as standard. It also carries two auxiliary switches plus a trip alarm and an electrical alarm switch (HQ type) for remote status feedback."},{"question":"Where can I buy 3VA2325-6HN32-0DL0 and what is the lead time?","answer":"This part is available to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ — submit one for a firm lead time and price."},{"question":"Will 3VA2325-6HN32-0DL0 drop into a panel designed for 3VA2225-5HN42-0BB0?","answer":"Both are SENTRON 3VA2-frame 3-pole MCCBs, so the mounting footprint and bus-bar spacing are the same. The main difference is the continuous rating and accessory configuration — verify the 250 A rating matches your load and that the auxiliary switch layout (2 aux + trip alarm + electrical alarm) fits your control wiring scheme before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HN32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HN32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}