{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HN32-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HN32-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HN32-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HN32-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-6HN32-0JH0, molded case circuit breaker, 3-pole, 250 A continuous, 242 kA breaking at 240 V, line protection, shunt trip, 2 aux + 1 alarm switch.","salesMarkdown":"The Siemens SENTRON 3VA2325-6HN32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. It is designed for line protection in distribution panels where the fault current can hit 242 kA at 240 V, 187 kA at 415 V, and still 121 kA at 500 V. That SCCR headroom means it can be placed at the main feeder without worrying about cascading failure into downstream gear. The 242 kA interrupting rating at 240 V is the headline number, but the 187 kA at 415 V is the one that matters for 400 V-class installations: it safely clears faults up to that level without upstream coordination headaches. That gives remote tripping capability and status feedback without an add-on module. No undervoltage release is fitted — if UVR is needed, this order code doesn't carry it. That covers unconditioned electrical rooms and outdoor enclosures in most climates.","metaTitle":"Siemens 3VA2325-6HN32-0JH0 SENTRON MCCB, 250 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2325-6HN32-0JH0 molded case circuit breaker, 250 A continuous, 3-pole, 242 kA at 240 V. Current production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"3 000 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-6HN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=187102&mlfb=3VA2325-6HN32-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HN32-0JH0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the 3VA2325-6HN32-0JH0?","answer":"250 A continuous, 3-pole, interrupting capacity 242 kA at 240 V, 187 kA at 415 V, 121 kA at 500 V, 7.5 kA at 690 V. Includes shunt trip and 2 aux + 1 alarm switch."},{"question":"Will the 3VA2325-6HN32-0JH0 drop into a panel designed for the 3VA1110-5EF32-0AM0?","answer":"Not without checking dimensions and ratings. The 3VA2325-6HN32-0JH0 is a 250 A, 3-pole frame with 138 mm width, while the 3VA1110-5EF32-0AM0 is a different frame size and amp rating. Verify panel cutout and bus bar spacing before substitution."},{"question":"How do I get pricing and availability for the 3VA2325-6HN32-0JH0?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ to confirm current pricing and availability at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HN32-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HN32-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}