{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-6HN32-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-6HN32-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-6HN32-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HN32-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-6HN32-0KA0, molded case circuit breaker, 250 A rated continuous current, 3-pole, 242 kA breaking capacity at 240 V, shunt trip release, line protection design.","salesMarkdown":"## Siemens 3VA2325-6HN32-0KA0 — 250 A MCCB with Shunt Trip Breaking capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V — figures that place it in the high-interrupting category for industrial feeders and large motor branch circuits. The breaker measures 248 mm high by 138 mm wide by 110 mm deep, fitting standard Siemens SENTRON mounting footprints. No auxiliary switch is fitted on this variant — the shunt trip is the only auxiliary release — so any remote status indication requires an add-on auxiliary switch block. The wide storage span matters for spares held in unheated warehouses or site containers.","metaTitle":"Siemens 3VA2325-6HN32-0KA0 MCCB, 250 A, 3-Pole, Shunt Trip","metaDescription":"Siemens SENTRON 3VA2325-6HN32-0KA0 molded case circuit breaker, 250 A continuous, 3-pole, 242 kA at 240 V. Line protection with shunt trip. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"3 000 A","Minimum":"3 000 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"37.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-6HN32-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=286261&mlfb=3VA2325-6HN32-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-6HN32-0KA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2325-6HN32-0KA0 at 415 V?","answer":"At 415 V the breaking capacity is 187 kA. At 240 V it is 242 kA, at 500 V it is 121 kA, and at 690 V it is 7.5 kA."},{"question":"What does the shunt trip release on this MCCB do?","answer":"The shunt trip (STL) allows remote opening of the breaker via a control voltage signal, independent of the thermal-magnetic trip mechanism. It is used for emergency-off, interlock, or supervisory shutdown circuits."},{"question":"Where can I buy 3VA2325-6HN32-0KA0?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-6HN32-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-6HN32-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}