{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2325-7MN32-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2325-7MN32-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2325-7MN32-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2325-7MN32-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2325-7MN32-0DH0, molded case circuit breaker, 3-pole, 250 A, motor protection design, 330 kA at 240 V.","salesMarkdown":"Three poles, 330 kA interrupting capacity at 240 V — that SCCR drops to 7.5 kA at 690 V, so the voltage class you feed it governs the fault-clearing headroom. ## SCCR and selectivity planning This breaker carries 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 7.5 kA at 690 V. The 4-to-17-second trip band (minimum to maximum) tells you the short-time delay range available for selectivity coordination with downstream feeders. ## Internal configuration and panel fit Phase-failure detection is built in; no ground-fault monitoring. Dimensions are 248 mm high, 138 mm wide, 110 mm deep — standard 3-pole MCCB footprint for a 250 A frame, so it swaps into an existing SENTRON panel bucket without re-drilling the mounting plate. ## Environmental and thermal limits Maximum power loss is 40 W — relevant for thermal rise inside a sealed enclosure. The flat 250 A rating from 40 through 70 °C means no derating curve to calculate for typical industrial panel ambient temperatures.","metaTitle":"Siemens 3VA2325-7MN32-0DH0 SENTRON MCCB, 250A, 3-Pole","metaDescription":"Siemens 3VA2325-7MN32-0DH0 SENTRON molded case circuit breaker, 250 A rated at 40-70°C, 3-pole, 330 kA SCCR at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"7.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"250 A","at 60 °C":"250 A","at 65 °C":"250 A","at 70 °C":"250 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"40 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2325-7MN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"55 000 W","operating power / at AC-3 / at 400 V":"110 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad4b9644ff5db6bf2edb958ed105bffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569855&mlfb=3VA2325-7MN32-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2325-7MN32-0DH0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2325-7MN32-0DH0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2325-7MN32-0DH0's listed depth?","answer":"The listed depth is 110 mm (4.33 in)."},{"question":"What compliance documentation does this brand provide for 3VA2325-7MN32-0DH0?","answer":"As a SENTRON MCCB, it carries the standard Siemens compliance documentation package including RoHS, REACH, and IEC/UL certifications applicable to the series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2325-7MN32-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2325-7MN32-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}