{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2340-5JQ42-0HL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2340-5JQ42-0HL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2340-5JQ42-0HL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2340-5JQ42-0HL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2340-5JQ42-0HL0, molded case circuit breaker, 4-pole, 400 A rated, 187 kA breaking at 240 VAC, line protection with communication function.","salesMarkdown":"The Siemens SENTRON 3VA2340-5JQ42-0HL0 is a 4-pole molded case circuit breaker rated 400 A continuous at 40 °C, with a full-scale setting of 400 A and an initial trip threshold of 80 A. Its interrupting capacity hits 187 kA at 240 VAC, dropping to 121 kA at 415/440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — so the voltage class of your distribution bus determines whether this breaker clears a fault or the fault clears upstream. Designed for line protection (cable/feeder), not motor branch, with a communication function for remote monitoring or trip indication. ## Thermal derating — the real-world current limit At 40, 45, and 50 °C ambient the breaker holds its 400 A rating. Above that it derates: 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. The 3VA2340-5JQ42-0HL0 measures 248 mm high, 184 mm wide, 110 mm deep — a 4-pole frame that fits standard SENTRON mounting plates. The 110 mm depth (4.33 in) leaves clearance behind a 200 mm deep enclosure door without interfering with gland plates or busbar shrouds. ## Operating range and power loss","metaTitle":"Siemens 3VA2340-5JQ42-0HL0 SENTRON MCCB, 400 A, 4-Pole, 187","metaDescription":"Siemens SENTRON 3VA2340-5JQ42-0HL0 molded case circuit breaker, 400 A rated, 4-pole, 187 kA breaking at 240 VAC. Line protection with communication. Current production. Quoted to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"184 mm","Height":"248 mm","Maximum":"4 000 A","Minimum":"600 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"7.5 kA","at 40 °C":"400 A","at 45 °C":"400 A","at 50 °C":"400 A","at 55 °C":"375 A","at 60 °C":"350 A","at 65 °C":"325 A","at 70 °C":"300 A","Depth [In]":"4.33 in","Width [In]":"7.24 in","Height [In]":"9.76 in","Initial Value":"80 A","Trip Indicator":"Yes","Number Of Poles":"4","Voltage Trigger":"Yes","lifecycle_stage":"current","Full-Scale Value":"400 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"96 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2340-5JQ42-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Summation current formation L + N conductor","Continuous Current / Rated Value":"400 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU560","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 100%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c1b3b6c5f6d67465025ac41848ceb75e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=175123&mlfb=3VA2340-5JQ42-0HL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2340-5JQ42-0HL0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2340-5JQ42-0HL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2340-5JQ42-0HL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}