{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2340-7HN32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2340-7HN32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2340-7HN32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2340-7HN32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2340-7HN32-0DL0, molded case circuit breaker, 3-pole, 400 A rated continuous current, 330 kA breaking capacity at 240 V, line protection design.","salesMarkdown":"## Siemens 3VA2340-7HN32-0DL0 — 400 A SENTRON MCCB, 3-Pole, Line Protection It carries a 330 kA breaking capacity at 240 V, stepping down to 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V — the high interrupting ratings at lower voltages suit it for fault-current-heavy service-entrance or main-breaker positions where upstream coordination demands full-rated SCCR. Thermal derating begins above 55 °C: it holds 400 A through 50 °C, then drops to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. A trip indicator is present. ## Integration Notes The 3VA2340-7HN32-0DL0 mounts into a standard SENTRON panel or enclosure footprint. The UVR coil requires a separate control voltage — verify the undervoltage release rating against your control circuit before wiring. The auxiliary switch set (2+1+1) provides status feedback for PLC or SCADA monitoring without an add-on module.","metaTitle":"Siemens 3VA2340-7HN32-0DL0 SENTRON MCCB, 400 A, 3-Pole","metaDescription":"Siemens SENTRON 3VA2340-7HN32-0DL0 molded case circuit breaker, 400 A continuous, 3-pole, 330 kA at 240 V. Current lifecycle stage, available to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"4 000 A","Minimum":"4 000 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"7.5 kA","at 40 °C":"400 A","at 45 °C":"400 A","at 50 °C":"400 A","at 55 °C":"385 A","at 60 °C":"370 A","at 65 °C":"355 A","at 70 °C":"340 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"98.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2340-7HN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"400 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"400 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c1b3b6c5f6d67465025ac41848ceb75e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=53735&mlfb=3VA2340-7HN32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2340-7HN32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2340-7HN32-0DL0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our sourcing network."},{"question":"What are the key ratings for 3VA2340-7HN32-0DL0?","answer":"Rated 400 A continuous at 40 °C, 3-pole, with a breaking capacity of 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V."},{"question":"What is the depth of 3VA2340-7HN32-0DL0?","answer":"The depth is 110 mm (4.33 in)."},{"question":"What auxiliary switches does 3VA2340-7HN32-0DL0 include?","answer":"It includes two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ configuration), plus an undervoltage release."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2340-7HN32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2340-7HN32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}