{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2450-7JQ32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2450-7JQ32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2450-7JQ32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2450-7JQ32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, 3VA2450-7JQ32-0AA0 molded case circuit breaker, 3-pole, 500 A, ETU560 electronic trip unit, line protection version with ground fault monitoring.","salesMarkdown":"The Siemens 3VA2450-7JQ32-0AA0 is a 3-pole SENTRON molded case circuit breaker rated for 500 A continuous current across a 40 °C to 50 °C ambient band — it holds full rating up to 50 °C before the thermal derate curve kicks in, which matters if your panel sits near process heat or a sunny wall. At 55 °C it still carries 477 A; at 70 °C it's 410 A. That ground-fault function is built in, not a bolt-on accessory. Interrupting capacity is 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 9 kA at 690 V. The 6 kA limited-to-1-second rating confirms it can hold in on a downstream bolted fault long enough for the branch breaker to clear. Communication function is onboard for monitoring network integration. IP40 front protection suits closed-panel use. Latching endurance is 15,000 operations.","metaTitle":"Siemens 3VA2450-7JQ32-0AA0 SENTRON MCCB, 500 A, 3-Pole, ETU5","metaDescription":"Siemens 3VA2450-7JQ32-0AA0 SENTRON molded case circuit breaker, 500 A continuous, 3-pole, ETU560 electronic trip unit. Line protection with ground fault monitoring. Sourced to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","title":"3VA2450-7JQ32-0AA0","Height":"248 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"9 kA","at 40 °C":"500 A","at 45 °C":"500 A","at 50 °C":"500 A","at 55 °C":"477 A","at 60 °C":"455 A","at 65 °C":"432 A","at 70 °C":"410 A","Depth [in]":"4.3 in","Width [in]":"5.4 in","Height [in]":"9.8 in","description":"circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit","Limited To 1 S":"6 kA","Number of poles":"3","Product version":"Line protection","lifecycle_stage":"current","Limited To 0.5 S":"6 kA","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"99 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-40 °C","Other Measurement Function":"No","Rated continuous current Iu":"500 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Summation current formation L-conductor","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"20","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"500 A","Adjustable response value current / lg max.":"500 A","Adjustable response value current / lg min.":"100 A","Adjustable response value current / li max.":"7 000 A","Adjustable response value current / li min.":"750 A","Adjustable response value current / lr min.":"200 A","Adjustable response value current / tg max.":"0.8 s","Adjustable response value current / tg min.":"0.05 s","Adjustable response value current / Isd max.":"5 000 A","Adjustable response value current / Isd min.":"300 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSIG","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"630 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7a4cb8e12c170fc74709edcea7fd13c1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=274798&mlfb=3VA2450-7JQ32-0AA0"},"ai":{"faq":[{"question":"What does the ETU560 trip unit do on this MCCB?","answer":"The ETU560 is an electronic trip unit with adjustable long-time pickup and delay, short-time and instantaneous settings, and built-in ground-fault monitoring via summation current formation on the L-conductor. It gives you coordination flexibility for selective tripping in a distribution panel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2450-7JQ32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2450-7JQ32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}