{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2463-5JP32-0AG0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2463-5JP32-0AG0","canonicalUrl":"https://aoctrl.com/siemens/3VA2463-5JP32-0AG0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2463-5JP32-0AG0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2463-5JP32-0AG0, 3-pole molded case circuit breaker, 630 A continuous, 187 kA at 240 V, line protection with communication and trip indicator.","salesMarkdown":"The Siemens 3VA2463-5JP32-0AG0 is a 3-pole SENTRON molded case circuit breaker rated for 630 A continuous current at 40 °C, with a maximum breaking capacity of 187 kA at 240 V and 121 kA at 415 V. The trip indicator gives a clear visual signal after a fault event, speeding up fault isolation on the floor. Breaking capacity drops as system voltage rises: 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. The minimum breaking current is 945 A, so it will clear low-level faults down to that threshold. The 630 A rating holds only at 40 °C ambient. Above that, derate linearly: 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, and 450 A at 70 °C. Maximum power loss is 162 W. ## Physical fit and auxiliary configuration That 110 mm depth matters for shallow backpan enclosures — measure your gutter space before ordering. The base switch is order code 3VA2463-5JP32-0AA0.","metaTitle":"Siemens 3VA2463-5JP32-0AG0 SENTRON MCCB, 630 A, 187 kA at 24","metaDescription":"Siemens 3VA2463-5JP32-0AG0 SENTRON molded case circuit breaker, 630 A continuous, 187 kA breaking at 240 V, 3-pole, line protection with communication. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"5 670 A","Minimum":"945 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"9 kA","at 40 °C":"630 A","at 45 °C":"600 A","at 50 °C":"570 A","at 55 °C":"540 A","at 60 °C":"510 A","at 65 °C":"480 A","at 70 °C":"450 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"162 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2463-5JP32-0AA0","Design Of The Auxiliary Switch":"1 auxiliary switch + 1 trip alarm switch HP","Design Of The Auxiliary Release":"Without auxiliary release","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"630 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"630 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB11","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ff193dd53a0856db1ca969741fab18b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=433356&mlfb=3VA2463-5JP32-0AG0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2463-5JP32-0AG0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2463-5JP32-0AG0?","answer":"Submit an RFQ through the storefront. The part is sourced to order via independent distribution; pricing and lead time are confirmed at quote time."},{"question":"What is 3VA2463-5JP32-0AG0's listed depth (110 mm) on this component line?","answer":"The depth is 110 mm (4.33 in). This is a critical dimension for shallow backpan enclosures."},{"question":"What is 3VA2463-5JP32-0AG0's listed width (138 mm) on this component line?","answer":"The width is 138 mm (5.43 in). Verify panel cutout spacing against this dimension."},{"question":"What compliance documentation does this brand provide for 3VA2463-5JP32-0AG0 (RoHS, REACH, UL, IEC)?","answer":"As a Siemens SENTRON product, the 3VA series carries UL and IEC certifications typical for molded case circuit breakers. RoHS and REACH declarations are available from Siemens documentation. Specific cert numbers are not listed in this evidence set."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2463-5JP32-0AG0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2463-5JP32-0AG0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}