{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2463-6JP32-0HL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2463-6JP32-0HL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2463-6JP32-0HL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2463-6JP32-0HL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA2463-6JP32-0HL0, 3-pole, 630 A continuous, line protection design with communication function.","salesMarkdown":"## Siemens 3VA2463-6JP32-0HL0 — 630 A SENTRON MCCB, Line Protection, Current Lifecycle It carries a 242 kA breaking capacity at 240 V and 187 kA at 415 V, with a derated 9 kA at 690 V. The adjustable thermal-magnetic trip unit covers a 945 A minimum to 5 670 A maximum range, letting you tune the instantaneous pickup to the fault current your downstream gear can withstand. The 110 mm depth and 138 mm width fit standard panel cutouts, and the communication function (likely PROFIBUS or PROFINET via an optional module) allows remote monitoring of breaker status and load current — useful for a maintenance planner tracking a 630 A feeder without walking the line. Above that, derate linearly: 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, and 450 A at 70 °C. If your panel ambient runs 50 °C, plan for 570 A maximum — the 630 A nameplate only holds below 40 °C. Maximum power loss is 162 W at rated load, which matters for enclosure heat rise calculations in a sealed cabinet. Ground-fault monitoring is absent — if you need GF protection, this variant is not it.","metaTitle":"Siemens 3VA2463-6JP32-0HL0 SENTRON MCCB, 630 A, 3-Pole","metaDescription":"Siemens 3VA2463-6JP32-0HL0 SENTRON molded case circuit breaker. 630 A continuous, 3-pole, line protection. Breaking capacity 242 kA at 240 V. Current lifecycle. Quoted to order aga","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"5 670 A","Minimum":"945 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"9 kA","at 40 °C":"630 A","at 45 °C":"600 A","at 50 °C":"570 A","at 55 °C":"540 A","at 60 °C":"510 A","at 65 °C":"480 A","at 70 °C":"450 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"162 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2463-6JP32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"630 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"630 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ff193dd53a0856db1ca969741fab18b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=311533&mlfb=3VA2463-6JP32-0HL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2463-6JP32-0HL0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2463-6JP32-0HL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2463-6JP32-0HL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}