{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2463-6JQ32-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2463-6JQ32-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2463-6JQ32-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2463-6JQ32-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, 3VA2463-6JQ32-0KA0, 3-pole molded case circuit breaker, 630 A rated continuous current, ETU560 electronic trip unit, breaking capacity 242 kA at 240 V.","salesMarkdown":"For a body-shop weld line where fault current can spike fast, the ETU560 lets you coordinate selectivity downstream without nuisance tripping that kills takt time. Breaking capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and still 40 kA at 690 V. That covers most industrial distribution panels feeding motor control centers or large drives. Current derating is published across the operating temperature range: 630 A at 40 °C, stepping down to 450 A at 70 °C. ## Integration — what fits inside the can The integrated auxiliary trip is order code 3VA9688-0BL33. No auxiliary contact block is included — order separately if you need status feedback to a PLC. Communication function is present on this variant, which means it can talk to a higher-level system for power monitoring or remote trip indication. No undervoltage release, no phase-failure detection, no trip indicator flag on the front.","metaTitle":"Siemens 3VA2463-6JQ32-0KA0 SENTRON MCCB, 630 A, 242 kA at 24","metaDescription":"Siemens 3VA2463-6JQ32-0KA0 SENTRON 3-pole molded case circuit breaker. Rated 630 A with ETU560 trip unit. Breaking capacity 242 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"40 kA","at 40 °C":"630 A","at 45 °C":"600 A","at 50 °C":"570 A","at 55 °C":"540 A","at 60 °C":"510 A","at 65 °C":"480 A","at 70 °C":"450 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"162 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"630 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2463-6JQ32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Summation current formation L-conductor","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"12","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"630 A","Adjustable response value current / lg max.":"630 A","Adjustable response value current / lg min.":"126 A","Adjustable response value current / li max.":"5 670 A","Adjustable response value current / li min.":"945 A","Adjustable response value current / lr min.":"252 A","Adjustable response value current / Isd max.":"5 670 A","Adjustable response value current / Isd min.":"378 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSIG","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"630 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"35 x 10","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"20 x 1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ff193dd53a0856db1ca969741fab18b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=181641&mlfb=3VA2463-6JQ32-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2463-6JQ32-0KA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2463-6JQ32-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2463-6JQ32-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}