{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2463-7HL32-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2463-7HL32-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2463-7HL32-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2463-7HL32-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2463-7HL32-0HA0, 630 A, 3-pole, 330 kA at 240 VAC, line protection, with shunt trip release.","salesMarkdown":"The 3-pole design covers three-phase systems; the 330 kA interrupting capacity at 240 VAC tells you it can clear a massive fault without rupturing — that's the kind of SCCR headroom you need at the service entrance or on a high-fault bus. At 415 V and 440 V it still holds 242 kA, and at 500 V it's 187 kA, so it's not a one-voltage wonder. At 40 °C ambient it carries the full 630 A; at 50 °C it's 593 A; at 60 °C it's 557 A; at 70 °C it's 520 A. If the panel ambient runs 55 °C, the real rating is 575 A, and the load must stay under that. The basic switch supplied is the 3VA2463-7HL32-0AA0. The 110 mm depth and 138 mm width fit the standard 3VA2 frame footprint; panel cutouts and busbar spacing match the rest of the 3VA2 family. The SENTRON 3VA2 series is Siemens' current-generation molded case breaker platform, so this order code is the primary part, not a legacy cross. If you're holding a BOM that calls out a 5SQ2370-2YA05 or similar, the 3VA2463-7HL32-0HA0 is a different frame and footprint — it will not drop into a panel cut out for the 5SQ series without rewiring and re-cutting the mounting holes. No direct mechanical interchange exists.","metaTitle":"Siemens 3VA2463-7HL32-0HA0 SENTRON MCCB, 630 A, 3-Pole, 330","metaDescription":"Siemens 3VA2463-7HL32-0HA0 SENTRON molded case circuit breaker, 630 A continuous, 3-pole, 330 kA interrupting at 240 VAC. Active production, quoted to order. Sourced via independen","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"138 mm","Height":"248 mm","Maximum":"5 670 A","Minimum":"945 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"9 kA","at 40 °C":"630 A","at 45 °C":"612 A","at 50 °C":"593 A","at 55 °C":"575 A","at 60 °C":"557 A","at 65 °C":"538 A","at 70 °C":"520 A","Depth [In]":"4.33 in","Width [In]":"5.43 in","Height [In]":"9.76 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"162 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2463-7HL32-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"630 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"630 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ff193dd53a0856db1ca969741fab18b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=335493&mlfb=3VA2463-7HL32-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2463-7HL32-0HA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2463-7HL32-0HA0 and get a price?","answer":"We source this part through independent distribution and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the interrupting capacity of 3VA2463-7HL32-0HA0 at different voltages?","answer":"At 240 V it's 330 kA; at 415 V and 440 V it's 242 kA; at 500 V it's 187 kA; at 690 V it drops to 9 kA."},{"question":"Does 3VA2463-7HL32-0HA0 have a shunt trip?","answer":"Yes, this variant includes a shunt trip release (STL) for remote tripping. It does not include an undervoltage release or ground-fault monitoring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2463-7HL32-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2463-7HL32-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}