{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2510-6HN32-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2510-6HN32-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2510-6HN32-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2510-6HN32-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2510-6HN32-0JA0, Molded case circuit breaker, 3-pole, 1000 A, Line protection, ETU350 electronic trip unit, 120 mm depth, 210 mm width, 320 mm height.","salesMarkdown":"It is configured for line protection and carries the ETU350 electronic trip unit, which gives you adjustable long-time (Ir), short-time (Isd), and instantaneous (Ii) response values — Ir adjustable up to 1000 A, Ii up to 10 000 A, and short-time delay tsd from 0.04 s to 0.4 s. This is the breaker you spec for a main feeder or large distribution panel where you need selectivity headroom and thermal-magnetic replacement logic. ## Breaking capacity and temperature derating Breaking capacity is the headline number for a main breaker: 242 kA at 240 V, 187 kA at 415 V, and still 74 kA at 690 V. That SCCR handles most utility-fault scenarios without cascading upstream — you can coordinate downstream feeders with confidence. On the thermal side, the breaker carries its full 1000 A from 40 °C through 55 °C, then derates to 955 A at 60 °C, 885 A at 65 °C, and 815 A at 70 °C. That flat top to 55 °C means no derating in a normal 40 °C panel environment; only a hot enclosure or adjacent high-loss gear pushes you into the derate curve. Dimensions: 320 mm height, 210 mm width, 120 mm depth. The 210 mm width (8.3 in) is the critical fit dimension for a panel layout — it occupies three standard 70 mm MCCB module slots on a DIN rail or mounting plate. ## Trip unit and adjustability ETU350 release is a basic electronic trip unit with LSI curves. Long-time response value tr adjustable from 0.5 to 17, short-time delay tsd from 0.04 to 0.4 s. No communication function; ground fault monitoring not included.","metaTitle":"Siemens 3VA2510-6HN32-0JA0 SENTRON MCCB, 1000 A, 3-Pole, Lin","metaDescription":"Siemens 3VA2510-6HN32-0JA0 SENTRON molded case circuit breaker, 1000 A rated, 3-pole, line protection, ETU350 release. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"120 mm","Width":"210 mm","Height":"320 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 690 V":"74 kA","at 40 °C":"1 000 A","at 45 °C":"1 000 A","at 50 °C":"1 000 A","at 55 °C":"1 000 A","at 60 °C":"955 A","at 65 °C":"885 A","at 70 °C":"815 A","Width [in]":"8.3 in","Height [in]":"12.6 in","Number of poles":"3","Product version":"Line protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"10 000","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"123 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"1 000 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Without","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.04 s","Adjustable response value current / Ir max.":"1 000 A","Adjustable response value current / li max.":"10 000 A","Adjustable response value current / li min.":"10 000 A","Adjustable response value current / lr min.":"400 A","Adjustable response value current / Isd max.":"10 000 A","Adjustable response value current / Isd min.":"1 500 A","Neutral conductors / upgradeable/retrofittable":"No","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"1 000 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"20 x 4"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=645436&mlfb=3VA2510-6HN32-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2510-6HN32-0JA0/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA2510-6HN32-0JA0's listed depth (120 mm) on this component line?","answer":"The depth is 120 mm. That is the dimension from the mounting plate to the front of the breaker body (excluding handle projection)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2510-6HN32-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2510-6HN32-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}