{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2563-6JP32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2563-6JP32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2563-6JP32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2563-6JP32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2563-6JP32-0AA0, molded case circuit breaker, 3-pole, 630 A, ETU550 electronic trip unit, breaking capacity 242 kA at 240 V, 187 kA at 415 V.","salesMarkdown":"## What this 630 A MCCB delivers in a distribution panel The Siemens SENTRON 3VA2563-6JP32-0AA0 is a 3-pole molded case circuit breaker rated for a continuous current of 630 A, with no derating needed across the full 40 °C to 70 °C ambient range — the same 630 A holds at every temperature step in the spec table. That thermal stability simplifies panel sizing: you don't have to oversize the frame for a hot enclosure. Breaking capacity runs from 242 kA at 240 V down to 73.5 kA at 690 V, which gives a site electrical engineer headroom for high-fault installations — think transformer secondaries or large motor control centers where SCCR coordination matters. The ETU550 electronic trip unit provides adjustable neutral protection (OFF, 20 % to 160 % of the phase setting) and a communication function for integration into a plant monitoring system — useful for a brownfield retrofit where you want breaker status on the SCADA without adding external aux contacts. Dimensions are 320 mm height, 210 mm width, and 120 mm depth. Front IP40 protection suits indoor panel mounting. Maximum power loss is 144 W.","metaTitle":"Siemens 3VA2563-6JP32-0AA0 SENTRON MCCB, 630A, 3-Pole, ETU55","metaDescription":"Siemens SENTRON 3VA2563-6JP32-0AA0 molded case circuit breaker, 630 A, 3-pole, ETU550 trip unit, 242 kA at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"120 mm","Width":"210 mm","title":"3VA2563-6JP32-0AA0","Height":"320 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"73.5 kA","at 40 °C":"630 A","at 45 °C":"630 A","at 50 °C":"630 A","at 55 °C":"630 A","at 60 °C":"630 A","at 65 °C":"630 A","at 70 °C":"630 A","Depth [In]":"4.72 in","Width [In]":"8.27 in","Height [In]":"12.6 in","description":"circuit breaker 3VA2 IEC frame 1000 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=630A overload protection Ir=250A...630A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"144 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Courant permanent assigné Iu":"630 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Adjustable response value current / li max.":"7 560 A","Adjustable response value current / li min.":"945 A","Neutral conductors / upgradeable/retrofittable":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"1 000 A","Mechanical Service Life (Switching Cycles) / Typical":"10 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"50 x 28 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"20 x 4 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c9fd37fa22cbeb51cb06d5bbec3a94bb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=645515&mlfb=3VA2563-6JP32-0AA0"},"ai":{"faq":[{"question":"What trip unit does this MCCB use?","answer":"It uses the ETU550 electronic trip unit with adjustable neutral protection (OFF, 20 % to 160 %) and communication capability."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2563-6JP32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2563-6JP32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}