{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4110-4ED34-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4110-4ED34-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4110-4ED34-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4110-4ED34-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded-case circuit breaker, 3VA4110-4ED34-0AA0, 3-pole, 100 A at 40 °C, TM210 thermal-magnetic release, 65 kA at 240 V AC, IP40 front.","salesMarkdown":"The Siemens 3VA4110-4ED34-0AA0 is a 3-pole SENTRON molded-case circuit breaker (MCCB) rated 100 A at 40 °C, with a TM210 thermal-magnetic release for system protection in distribution panels and motor control centers. Its interrupting capacity hits 65 kA at 240 V AC and 25 kA at 480 V AC — that's SCCR headroom for most industrial feeders and downstream coordination without cascading upstream. Rated operating voltage goes to 690 V AC, and the breaker handles ambient temperatures from -25 °C to 70 °C, with a 22.8 W max power loss at full load. The 100 A rating at 40 °C is the continuous current you can push through it in a typical 40 °C panel ambient. Derate to 87 A at 70 °C if the enclosure runs hot — the thermal curve matters for real-world loading. 65 kA at 240 V means it safely interrupts a fault up to that level without blowing apart or welding contacts, so you can place it near high-capacity transformers or upstream of smaller branch breakers. No adjustable trip unit, no ground-fault module, no communication. It's a straight system-protection breaker for fixed-load feeders. The breaker measures 76.2 mm wide, 129.4 mm tall, and 75.1 mm deep.","metaTitle":"Siemens 3VA4110-4ED34-0AA0 SENTRON MCCB, 100 A, 65 kA at 240","metaDescription":"Siemens 3VA4110-4ED34-0AA0 SENTRON molded-case circuit breaker, 3-pole, 100 A at 40 °C, 65 kA interrupting at 240 V AC. TM210 release. Current production, available to order. Reque","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"76.2 mm","title":"3VA4110-4ED34-0AA0","Height":"129.4 mm","Maximum":"1 s","Minimum":"1 s","at 240 V":"65 kA","at 480 V":"25 kA","at 40 °C":"100 A","at 45 °C":"98 A","at 50 °C":"96 A","at 55 °C":"93 A","at 60 °C":"91 A","at 65 °C":"89 A","at 70 °C":"87 A","Depth [In]":"2.96 in","Width [In]":"3 in","Height [In]":"5.09 in","description":"circuit breaker 3VA4 UL frame 125 breaking capacity class S 25kA @ 480 V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In clamp connection","Trip Indicator":"No","at 480 Y/277 V":"25 kA","at 600 Y/347 V":"14 kA","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded-case circuit breaker","Undervoltage Release":"No","Design Of The Product":"System protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"22.8 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","Product Extension / Optional / Motor Drive":"No","product designation / according to UL file":"SEAB","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","electrical endurance (operating cycles) / at 480 V":"8 000","electrical endurance (operating cycles) / at 600 V":"4 000","marking / according to UL 489 / 100%-rated breaker":"No","Mechanical Service Life (Operating Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"Infeed side: Low tab","Arrangement Of Electrical Connectors / For Main Current Circuit":"output side: circular conductor connection"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$132.08","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e3c5a0db84926dee35e456cc1567cb64.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058297&mlfb=3VA4110-4ED34-0AA0"},"ai":{"faq":[{"question":"Does this MCCB have an adjustable trip unit or ground-fault protection?","answer":"No. The TM210 release is a fixed thermal-magnetic trip — no adjustable settings, no ground-fault monitoring, and no communication module. It's a straight system-protection breaker."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4110-4ED34-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4110-4ED34-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}