{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4111-6ED34-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4111-6ED34-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4111-6ED34-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4111-6ED34-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA4111-6ED34-0AA0, 3-pole molded-case circuit breaker, 110 A at 40 °C, TM210 thermal-magnetic release, 100 kA at 240 V, 65 kA at 480 V.","salesMarkdown":"## Siemens SENTRON 3VA4111-6ED34-0AA0 — 110 A MCCB with TM210 Release The Siemens SENTRON 3VA4111-6ED34-0AA0 is a 3-pole molded-case circuit breaker (MCCB) rated for 110 A continuous at 40 °C, with a TM210 thermal-magnetic overcurrent release. The continuous current rating is temperature-dependent. At 40 °C the breaker carries 110 A; at 50 °C it derates to 106 A; at 60 °C to 101 A; at 70 °C to 97 A. ## Interrupting Ratings and Selectivity At 600 Y/347 V the rating drops to 25 kA. For a 480 V panel with an available fault current of, say, 50 kA, this breaker provides headroom. The TM210 release has a fixed instantaneous pickup (Ii) of 1100 A — ten times the continuous rating — which is typical for a thermal-magnetic MCCB protecting a feeder or large motor branch. The adjustable long-time (Ir) range is not listed, so the TM210 likely has a fixed thermal element calibrated at 110 A. Dimensions are 76.2 mm wide, 129.4 mm tall, and 75.1 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures. No neutral conductor upgrade or ground-fault monitoring option is available on this variant.","metaTitle":"Siemens 3VA4111-6ED34-0AA0 SENTRON MCCB, 110A, 100kA at 240V","metaDescription":"Siemens SENTRON 3VA4111-6ED34-0AA0 molded-case circuit breaker. 3-pole, 110 A at 40 °C, TM210 release. 100 kA at 240 V, 65 kA at 480 V. Current lifecycle stage. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"76.2 mm","Height":"129.4 mm","at 240 V":"100 kA","at 480 V":"65 kA","at 40 °C":"110 A","at 45 °C":"108 A","at 50 °C":"106 A","at 55 °C":"103 A","at 60 °C":"101 A","at 65 °C":"99 A","at 70 °C":"97 A","Depth [In]":"3 in","Width [In]":"3 in","Height [In]":"5.1 in","at 480 Y/277 V":"65 kA","at 600 Y/347 V":"25 kA","Number Of Poles":"3","Product version":"System protection","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded-case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25.4 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"110 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Adjustable response value current / li max.":"1 100 A","Adjustable response value current / li min.":"1 100 A","marking / acc. to UL 489 / 100%-rated breaker":"No","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"125 A","electrical endurance (switching cycles) / at 480 V":"8 000","electrical endurance (switching cycles) / at 600 V":"4 000","Mechanical Service Life (Switching Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"Infeed side: Low tab","Arrangement Of Electrical Connectors / For Main Current Circuit":"Load side: Circular conductor terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (8 AWG - 3/0)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e3c5a0db84926dee35e456cc1567cb64.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058115&mlfb=3VA4111-6ED34-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA4111-6ED34-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA4111-6ED34-0AA0 fit in a panel designed for 3VA1010-2ED32-0JA0?","answer":"The 3VA4111-6ED34-0AA0 is a 3-pole MCCB in the same SENTRON family, but the 3VA1010-2ED32-0JA0 is a different frame/rating. Physical dimensions (76.2 mm wide, 129.4 mm tall, 75.1 mm deep) are standard for the class, but verify mounting hole pattern and busbar spacing against the existing panel layout before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4111-6ED34-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4111-6ED34-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}