{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4135-4ED34-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4135-4ED34-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4135-4ED34-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4135-4ED34-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded-case circuit breaker, 3VA4 series, 3-pole, 35 A, TM210 thermal-magnetic release, 65 kA at 240 V, 25 kA at 480 V, IP40 front, current lifecycle.","salesMarkdown":"The interrupting ratings are 65 kA at 240 V and 25 kA at 480 V — that 65 kA figure at 240 V means it can safely clear a fault current up to that level on a 240 VAC line without welding contacts or rupturing the case, which is the spec that decides whether this breaker holds on a high-fault panel. The 25 kA at 480 V covers standard 480 VAC distribution. The TM210 release gives a fixed instantaneous trip at 350 A (10× Ir), so it's sized for motor or general branch-circuit protection where you want magnetic trip above inrush. The breaker holds its full 35 A rating from 40 °C up to 50 °C, then derates to 34 A at 55 °C and 32 A at 70 °C — so in a warm enclosure near the top of a panel, you still get nearly full current. Dimensions are 76.2 mm wide, 129.4 mm high, 75.1 mm deep, which is the standard 3-pole MCCB footprint for a SENTRON 3VA4 frame.","metaTitle":"Siemens SENTRON 3VA4135-4ED34-1AA0 MCCB, 35 A, 65 kA at 240","metaDescription":"Siemens SENTRON 3VA4135-4ED34-1AA0 3-pole molded-case circuit breaker. Rated 35 A continuous, 65 kA interrupting at 240 V. TM210 release. Current lifecycle. Sourced to order. Reque","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"76.2 mm","Height":"129.4 mm","at 240 V":"65 kA","at 480 V":"25 kA","at 40 °C":"35 A","at 45 °C":"35 A","at 50 °C":"35 A","at 55 °C":"34 A","at 60 °C":"33 A","at 65 °C":"33 A","at 70 °C":"32 A","Depth [in]":"3 in","Width [in]":"3 in","Height [in]":"5.1 in","at 480 Y/277 V":"25 kA","at 600 Y/347 V":"14 kA","Number of poles":"3","Product version":"System protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded-case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"9.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"35 A","Ground fault monitoring version":"Without","Design of the overcurrent release":"TM210","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"35 A","Adjustable response value current / li max.":"350 A","Adjustable response value current / li min.":"350 A","Adjustable response value current / lr min.":"35 A","Marking / acc. to UL 489 / 100%-rated breaker":"No","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"S","Max. rated operational current of the frame size":"125 A","Mechanical service life (switching cycles) / typical":"15 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2f5f9416f23e44383b2107af7db46916.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058207&mlfb=3VA4135-4ED34-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA4135-4ED34-1AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA4135-4ED34-1AA0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request with your quantity and target delivery window; availability and current pricing are confirmed at quote time."},{"question":"What are the interrupting ratings for 3VA4135-4ED34-1AA0?","answer":"65 kA at 240 V, 25 kA at 480 V, and 14 kA at 600 Y/347 V. The 65 kA at 240 V is the headline figure — it handles high-fault panels at the common 240 V level without needing a current-limiting fuse upstream."},{"question":"What is the continuous current rating and how does it derate with temperature?","answer":"Rated 35 A continuous. It holds 35 A from 40 °C to 50 °C, then derates to 34 A at 55 °C, 33 A at 65 °C, and 32 A at 70 °C. In a warm enclosure, you lose only about 3 A at the top of the operating range."},{"question":"What compliance documentation is available for this MCCB?","answer":"As a Siemens SENTRON product, it carries the standard IEC/EN 60947-2 certification for molded-case circuit breakers. The marking reference to UL 489 is noted on the variant. Specific RoHS and REACH declarations are available from Siemens on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4135-4ED34-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4135-4ED34-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}