{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4160-6ED34-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4160-6ED34-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4160-6ED34-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4160-6ED34-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA4160-6ED34-0AA0, 3-pole molded-case circuit breaker, 60 A (40 °C), 100 kA at 240 V, TM210 thermal-magnetic release, system protection design.","salesMarkdown":"The Siemens 3VA4160-6ED34-0AA0 is a 3-pole SENTRON molded-case circuit breaker rated 60 A at 40 °C ambient, with a TM210 thermal-magnetic trip unit designed for system protection — meaning it handles branch-circuit fault interruption and overload protection in a distribution panel, not motor-starting duty with high inrush. At 600 Y/347 V it still holds 25 kA. It's a straight-ahead overcurrent protector for a fixed-load feeder or a lighting panel where you don't need selectivity tuning. ## Thermal derating — real panel ambient, not the nameplate At 50 °C it's 58 A; at 60 °C it's 55 A; at 70 °C it's 53 A. Front protection is IP40 — sealed against tools and fingers, not against dust ingress. In a cement plant or grain-handling environment, mount it in a gasketed enclosure; the breaker itself won't keep cement dust out of the mechanism. That covers unheated warehouses and outdoor cabinets in most climates, but the derating curve is the binding limit once the breaker is loaded. Maximum power loss is 13.9 W at rated load. That's low enough for dense panel layouts, but if you're stacking five of these in a row, account for the heat in the enclosure sizing calculation.","metaTitle":"Siemens 3VA4160-6ED34-0AA0 SENTRON MCCB, 60 A, 100 kA at 240","metaDescription":"Siemens 3VA4160-6ED34-0AA0 SENTRON molded-case circuit breaker, 3-pole, 60 A rated at 40 °C, 100 kA breaking at 240 V. TM210 release. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"76.2 mm","title":"3VA4160-6ED34-0AA0","Height":"129.4 mm","Maximum":"1 s","Minimum":"1 s","at 240 V":"100 kA","at 480 V":"65 kA","at 40 °C":"60 A","at 45 °C":"59 A","at 50 °C":"58 A","at 55 °C":"56 A","at 60 °C":"55 A","at 65 °C":"54 A","at 70 °C":"53 A","Depth [In]":"2.96 in","Width [In]":"3 in","Height [In]":"5.09 in","description":"circuit breaker 3VA4 UL frame 125 breaking capacity class H 65kA @ 480 V 3-pole, line protection TM210, FTFM, In=60A overload protection Ir=60A fixed short-circuit protection Ii=10 x In clamp connection","Trip Indicator":"No","at 480 Y/277 V":"65 kA","at 600 Y/347 V":"25 kA","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded-case circuit breaker","Undervoltage Release":"No","Design Of The Product":"System protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.9 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","Product Extension / Optional / Motor Drive":"No","product designation / according to UL file":"HEAB","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","electrical endurance (operating cycles) / at 480 V":"8 000","electrical endurance (operating cycles) / at 600 V":"4 000","marking / according to UL 489 / 100%-rated breaker":"No","Mechanical Service Life (Operating Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"Infeed side: Low tab"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$124.46","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7aaa2d0d7ff0b8cad78e1a824aa9fef7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058421&mlfb=3VA4160-6ED34-0AA0"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA4160-6ED34-0AA0 at 480 V?","answer":"65 kA at 480 V AC, and 100 kA at 240 V AC. At 600 Y/347 V it's rated 25 kA."},{"question":"Where can I buy 3VA4160-6ED34-0AA0 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Does 3VA4160-6ED34-0AA0 have a ground-fault or communication option?","answer":"No. This variant has no ground-fault monitoring, no communication function, and no undervoltage release. It's a plain thermal-magnetic breaker for basic overcurrent protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4160-6ED34-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4160-6ED34-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}