{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4170-6ED34-3AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4170-6ED34-3AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4170-6ED34-3AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4170-6ED34-3AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA4 UL Frame 125, 3-pole circuit breaker, 70 A TM210 line protection, 65 kA interrupting capacity at 480 V, fixed Ir=70 A, fixed Ii=10 x In, FTFM.","salesMarkdown":"The Siemens 3VA4170-6ED34-3AA0 is a 3-pole molded-case circuit breaker in the 3VA4 UL Frame 125 series, rated for line protection with a TM210 thermal-magnetic trip unit. The overload protection is set permanently at Ir=70 A, and the short-circuit pickup is fixed at Ii=10 x In (700 A). That fixed trip setting simplifies BOM consistency: every unit delivers the same protection curve, no field-adjustment errors. The FTFM (Fixed Thermal, Fixed Magnetic) trip unit eliminates the need for calibration or seal-wire management on the line. The 3-pole construction fits standard 3-phase feeder or branch circuits in switchboards and panelboards rated up to 480 V. Export control is straightforward: AL N / ECCN EAR99, so no special licensing is required for most destinations. RoHS compliance is confirmed since 13-05-19, and REACH Article 33 disclosure notes lead (CAS 7439-92-1) above 0.1% w/w in the current candidate list — a standard declaration for electrical components with lead-bearing alloys. The 3VA4 UL Frame 125 breaker mounts directly to a panelboard bus or can be installed in a standalone enclosure. The 3-pole form factor with line and load lugs accepts copper or aluminum conductors sized for the 70 A continuous rating. The thermal-magnetic trip unit is non-interchangeable — the TM210 is integral to the frame, so the protection settings are fixed at the factory. No accessory slot for shunt trips or auxiliary contacts is described in the base listing; verify the specific order code suffix if add-on modules are required for remote trip indication or undervoltage release.","metaTitle":"Siemens 3VA4170-6ED34-3AA0 Circuit Breaker, 70 A, 65 kA @ 48","metaDescription":"Siemens 3VA4170-6ED34-3AA0 circuit breaker, 70 A, 65 kA @ 480 V, 3-pole, UL Frame 125. Active production. RoHS/REACH compliant. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Group Code":"P360","Product Group":"5385","Product class":"C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.","Quantity Unit":"1 Piece","Product Family":"Ordering Data Overview","lifecycle_stage":"current","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : EAR99","Packaging dimensions (L x W x H)":"472.00 x 396.00 x 213.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 13-05-19","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48b9970ffdbbbf22a9798b95ba3654f2.pdf","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/3VA4170-6ED34-3AA0?tree=CatalogTree","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA4170-6ED34-3AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA4170-6ED34-3AA0?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront; the made-to-order status means the factory schedule and current material costs determine the lead time and price — no shelf stock exists."},{"question":"What is the interrupting rating of this breaker?","answer":"The 3VA4170-6ED34-3AA0 is rated 65 kA at 480 V, breaking capacity class H. That is sufficient for most industrial main and feeder applications with high available fault current."},{"question":"What compliance documentation does this brand provide for 3VA4170-6ED34-3AA0 (RoHS, REACH, UL, IEC)?","answer":"RoHS compliance is confirmed since 13-05-19. REACH Article 33 disclosure identifies lead (CAS 7439-92-1) above 0.1% w/w. The breaker is UL-listed under the 3VA4 UL Frame 125 series. Export control is AL N / ECCN EAR99."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4170-6ED34-3AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4170-6ED34-3AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}