{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4190-6ED34-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4190-6ED34-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4190-6ED34-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4190-6ED34-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA4190-6ED34-0AA0, 3-pole molded-case circuit breaker, 90 A at 40 °C, 100 kA at 240 VAC, TM210 thermal-magnetic release.","salesMarkdown":"Its 100 kA interrupting rating at 240 VAC and 65 kA at 480 VAC mean it can clear high-fault currents without upstream coordination issues — critical for feeder circuits in mills or processing plants where fault levels run high. The 690 VAC operating voltage covers 480 V and 600 V class systems, including 600Y/347 V where it still interrupts 25 kA. IP40 on the front keeps dust out of the mechanism but isn't rated for washdown; mount it inside a sealed enclosure if the environment is wet or dusty.","metaTitle":"Siemens 3VA4190-6ED34-0AA0 SENTRON MCCB, 90 A, 100 kA at 240","metaDescription":"Siemens SENTRON 3VA4190-6ED34-0AA0 molded-case circuit breaker, 3-pole, 90 A (40 °C), 100 kA at 240 VAC. TM210 release. Current production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"76.2 mm","Height":"129.4 mm","Maximum":"1 s","Minimum":"1 s","at 240 V":"100 kA","at 480 V":"65 kA","at 40 °C":"90 A","at 45 °C":"88 A","at 50 °C":"86 A","at 55 °C":"84 A","at 60 °C":"81 A","at 65 °C":"79 A","at 70 °C":"77 A","Depth [In]":"2.96 in","Width [In]":"3 in","Height [In]":"5.09 in","Trip Indicator":"No","at 480 Y/277 V":"65 kA","at 600 Y/347 V":"25 kA","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded-case circuit breaker","Undervoltage Release":"No","Design Of The Product":"System protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"17.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","Product Extension / Optional / Motor Drive":"No","product designation / according to UL file":"HEAB","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","electrical endurance (operating cycles) / at 480 V":"8 000","electrical endurance (operating cycles) / at 600 V":"4 000","marking / according to UL 489 / 100%-rated breaker":"No","Mechanical Service Life (Operating Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"Infeed side: Low tab","Arrangement Of Electrical Connectors / For Main Current Circuit":"output side: circular conductor connection"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/64b8a3dd65d7e0d19359ee8da9307512.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058267&mlfb=3VA4190-6ED34-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA4190-6ED34-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA4190-6ED34-0AA0 and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What are the interrupting ratings of 3VA4190-6ED34-0AA0?","answer":"It interrupts 100 kA at 240 VAC, 65 kA at 480 VAC, and 25 kA at 600Y/347 V. Those numbers cover most industrial service-entrance and feeder applications."},{"question":"What is the depth of 3VA4190-6ED34-0AA0?","answer":"The depth is 75.1 mm, width 76.2 mm, height 129.4 mm — a compact 3-pole footprint that fits standard panel layouts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4190-6ED34-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4190-6ED34-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}