{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4195-4ED24-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4195-4ED24-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4195-4ED24-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4195-4ED24-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA4195-4ED24-0AA0, 2-pole molded-case circuit breaker, 15 A at 40 °C, 65 kA interrupting at 240 V, TM210 thermal-magnetic release, system protection version.","salesMarkdown":"## Siemens 3VA4195-4ED24-0AA0 — 15 A MCCB with 65 kA interrupting capacity The Siemens SENTRON 3VA4195-4ED24-0AA0 is a 2-pole molded-case circuit breaker (MCCB) rated 15 A at 40 °C, with a TM210 thermal-magnetic release. Its interrupting capacity hits 65 kA at 240 V and 25 kA at 480 V — enough headroom for most distribution panels on a 480Y/277 V service where it still delivers 25 kA. The fixed instantaneous trip is set at 300 A (li min and max both 300 A), so it's a straight thermal-magnetic device, not a selective or electronic-trip variant. This is the system protection version (not a motor circuit protector or switch-disconnector), designed for branch-circuit and feeder protection in commercial and industrial panels. It carries a UL file designation SEAB, meaning it's UL 489 listed for the North American market. The 15 A rating holds at 40 °C and 45 °C, then derates to 14 A at 50–60 °C, and 13 A at 65–70 °C. Plan your continuous load at 80 % of the derated value per NEC. The 65 kA at 240 V is the high-end interrupting rating; at 600 Y/347 V it drops to 14 kA, so verify the available fault current at the installation point. It's a straightforward thermal-magnetic MCCB with no add-on modules. The 3VA4195-4ED24-0AA0 measures 75.1 mm deep, 50.8 mm wide, and 129.4 mm high. Depth at 75.1 mm (3 inches) means it clears most shallow enclosures, but check the door clearance if you're mounting a rotary handle or extended shaft.","metaTitle":"Siemens 3VA4195-4ED24-0AA0 SENTRON MCCB, 15 A, 2-Pole, 65 kA","metaDescription":"Siemens SENTRON 3VA4195-4ED24-0AA0 molded-case circuit breaker, 15 A rated, 2-pole, 65 kA at 240 V. TM210 release. Current lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"50.8 mm","Height":"129.4 mm","at 240 V":"65 kA","at 480 V":"25 kA","at 40 °C":"15 A","at 45 °C":"15 A","at 50 °C":"14 A","at 55 °C":"14 A","at 60 °C":"14 A","at 65 °C":"13 A","at 70 °C":"13 A","Depth [In]":"3 in","Width [In]":"2 in","Height [In]":"5.1 in","at 480 Y/277 V":"25 kA","at 600 Y/347 V":"14 kA","Number Of Poles":"2","Product version":"System protection","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded-case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"6.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"15 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","product designation / according to UL file":"SEAB","Adjustable response value current / li max.":"300 A","Adjustable response value current / li min.":"300 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Max. rated operational current of the frame size":"125 A","electrical endurance (switching cycles) / at 480 V":"8 000","electrical endurance (switching cycles) / at 600 V":"4 000","marking / according to UL 489 / 100%-rated breaker":"No","Mechanical Service Life (Switching Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"Infeed side: Low tab","Arrangement Of Electrical Connectors / For Main Current Circuit":"Load side: Circular conductor terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (14 AWG - 8 AWG)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/64b8a3dd65d7e0d19359ee8da9307512.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058272&mlfb=3VA4195-4ED24-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA4195-4ED24-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA4195-4ED24-0AA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the depth of 3VA4195-4ED24-0AA0?","answer":"The depth is 75.1 mm (3 inches)."},{"question":"What compliance documentation does Siemens provide for 3VA4195-4ED24-0AA0?","answer":"The breaker carries UL file designation SEAB (UL 489 listing) and is designed to IEC 60947-2 standards. It is RoHS and REACH compliant per Siemens standard documentation. The reference code per IEC 81346-2 is Q."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4195-4ED24-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4195-4ED24-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}