{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA4195-4ED34-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA4195-4ED34-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA4195-4ED34-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA4195-4ED34-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"SENTRON 3VA4195-4ED34-0AA0, 3-pole molded-case circuit breaker, 15 A at 40 °C, 65 kA at 240 V, TM210 release.","salesMarkdown":"This SENTRON 3VA4195-4ED34-0AA0 is a 3-pole molded-case circuit breaker (MCCB) rated 15 A at 40 °C, with a TM210 thermal-magnetic release. At 50 °C it derates to 14 A; at 70 °C it holds 13 A. That derating curve matters if the breaker sits near transformers or drives that push the enclosure above 40 °C. At 480 V the interrupting rating drops to 25 kA, still adequate for most motor-control-center feeds. The 3VA4195-4ED34-0AA0 measures 76.2 mm wide, 75.1 mm deep, and 129.4 mm tall.","metaTitle":"SENTRON 3VA4195-4ED34-0AA0 MCCB, 3-pole, 15 A, 65 kA at 240","metaDescription":"SENTRON 3VA4195-4ED34-0AA0 molded-case circuit breaker, 3-pole, 15 A rated, 65 kA at 240 V. TM210 release. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"75.1 mm","Width":"76.2 mm","Height":"129.4 mm","at 240 V":"65 kA","at 480 V":"25 kA","at 40 °C":"15 A","at 45 °C":"15 A","at 50 °C":"14 A","at 55 °C":"14 A","at 60 °C":"14 A","at 65 °C":"13 A","at 70 °C":"13 A","Depth [In]":"2.96 in","Width [In]":"3 in","Height [In]":"5.09 in","Trip Indicator":"No","at 480 Y/277 V":"25 kA","at 600 Y/347 V":"14 kA","Number Of Poles":"3","Product version":"System protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded-case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"9.8 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"690 V","Product Extension / Optional / Motor Drive":"No","product designation / according to UL file":"SEAB","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","electrical endurance (switching cycles) / at 480 V":"8 000","electrical endurance (switching cycles) / at 600 V":"4 000","marking / according to UL 489 / 100%-rated breaker":"No","Mechanical Service Life (Switching Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"Infeed side: Low tab","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (14 AWG - 8 AWG)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/64b8a3dd65d7e0d19359ee8da9307512.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1058274&mlfb=3VA4195-4ED34-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA4195-4ED34-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA4195-4ED34-0AA0 and what is the lead time?","answer":"This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest lead time."},{"question":"What are the interrupting ratings for this MCCB?","answer":"At 240 V AC the interrupting capacity is 65 kA; at 480 V AC it is 25 kA; at 600 Y/347 V it is 14 kA."},{"question":"What does the TM210 release designation mean?","answer":"TM210 is a thermal-magnetic overcurrent release — the thermal element handles overload protection, the magnetic element handles short-circuit protection. It's a fixed-trip design, not adjustable."},{"question":"What compliance documentation is available for this SENTRON breaker?","answer":"The product carries UL file SEAB, indicating UL 489 listing for molded-case circuit breakers. Standard RoHS and REACH declarations are available from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA4195-4ED34-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA4195-4ED34-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}