{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA9114-0RL10","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA9114-0RL10","canonicalUrl":"https://aoctrl.com/siemens/3VA9114-0RL10","factsUrl":"https://aoctrl.com/api/mcp/products/3VA9114-0RL10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCD320 Basic residual current device module, type A, 4-pole, 160 A, selectable residual current 0.03–5 A, instantaneous, load-side mounted, for 3VA1.","salesMarkdown":"The Siemens 3VA9114-0RL10 is a SENTRON RCD320 Basic residual current device module — a Type A RCD designed for load-side mounting on 3VA1 molded-case circuit breakers. It provides ground-fault protection for a 4-pole circuit rated at 160 A (AC) with a selectable residual current threshold from 0.03 A up to 5 A, covering the range from 30 mA personal-protection sensitivity through 5 A equipment-protection levels. This makes it suitable for mixed-load panels where electronic loads are present alongside conventional resistive or motor circuits. The module mounts on the load side of a 3VA1 breaker and connects via busbar connection. Infeed can be from the top or the bottom, which simplifies busbar routing in crowded enclosures. Screw fixing secures it to the DIN rail or mounting plate — no special tooling required for panel integration. The 160 A operational current (AC) matches the frame size of the host 3VA1 breaker — this is not a standalone RCD but a modular add-on that shares the breaker's current path. If your circuit is fused or breakered at 160 A or less, this module stays within its continuous rating. Seven selectable residual current thresholds (0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, and 5 A) let you dial in the trip sensitivity without swapping hardware. The 30 mA setting covers personnel protection per IEC 60364; the higher settings are used for fire protection or equipment protection where nuisance tripping from leakage currents must be avoided. Rated for 50/60 Hz operation up to 60 Hz, with an operating voltage range of 100–480 V AC. The module includes a pre-alarm indication at 30% of the set residual current value, which can flag deteriorating insulation before a trip occurs. Siemens SENTRON component. Sealable design supports tamper-proof installation. The module has an electrical trip indicator (mechanical flag) for local status — no communication-based remote tripping or alarm output is provided on this variant. For applications requiring remote signaling, a separate auxiliary contact or communication module would need to be added at the breaker level.","metaTitle":"Siemens 3VA9114-0RL10 SENTRON RCD320, 4P 160A Type A","metaDescription":"Siemens 3VA9114-0RL10 SENTRON residual current device module, 4-pole, 160 A, Type A, selectable 0.03–5 A. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","title":"3VA9114-0RL10","Height":"100 mm","Maximum":"80 °C","Minimum":"-40 °C","description":"residual current device RCD320 Basic RCD type A load side mounted rated resid. current 0.03...5A at 50/60Hz tv instantaneous 4-pole In=160A Ue=100-480V accessory for: 3VA1","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"screw fixing","Product Brand Name":"SENTRON","Product Designation":"Accessories","Design Of The Product":"Residual current protection module type A","power loss [W] / maximum":"6.1 W","Product Feature / Sealable":"Yes","protection class IP / on the front":"IP40","Type Of Trip Indicator / Electrical":"Yes","Type Of Trip Indicator / Communication":"No","Response Value / Of The Residual Current":"0.03;0.05;0.1;0.3;0.5;1;3;5","operational current / at AC / rated value":"160 A","Operating Frequency / Rated Value / Maximum":"60 Hz","Product Function / Remote-Controlled Tripping":"No","position / of the infeed / on the RCD component":"Top or bottom","Product Function / Integrated / Alarm Management":"Pre-alarm indication 30%","Set Values / Of The Limit Value Of Not Tripping Time":"0;","product function / selectable RCD or monitoring mode":"No","Product Function / Selectable Tripping Characteristic":"No","Type Of Electrical Connection / For Main Current Circuit":"busbar connection","Product Function / Communication With Residual Current Equipment":"No"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/850b23bb051ee496fd0a002fad11636b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=312494&mlfb=3VA9114-0RL10"},"ai":{"faq":[{"question":"Does the 3VA9114-0RL10 have a remote trip or communication function?","answer":"No. This variant has no remote-controlled tripping, no communication interface, and no Modbus or other fieldbus connectivity. It provides a local electrical trip indicator only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA9114-0RL10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA9114-0RL10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}