{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VM1063-3ED32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VM1063-3ED32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VM1063-3ED32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VM1063-3ED32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VM1063-3ED32-0AA0, molded case circuit breaker, 3-pole, TM210 thermal-magnetic release, 63 A at 40 °C, 76 kA breaking capacity at 240 V.","salesMarkdown":"The Siemens 3VM1063-3ED32-0AA0 is a SENTRON molded case circuit breaker (MCCB) with a TM210 thermal-magnetic overcurrent release, rated 63 A at 40 °C across a 3-pole configuration. Breaking capacity reaches 76 kA at 240 V AC, stepping down to 53 kA at 415 V, 32 kA at 440 V, and 8 kA at 500 V, so it's sized for high-fault industrial grids where the available short-circuit current is known and the 240 V or 415 V rating is the one that governs fit. The 63 A rating holds flat from 40 °C to 50 °C, then derates gradually: 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C. Maximum power loss is 22 W, so ventilation in a sealed cabinet needs to account for that heat. It's a straightforward line-protection device: set the load, wire it, and it trips on overload or short circuit. The 1 s minimum trip time on the magnetic element means very high short-circuit currents (above the magnetic pickup threshold) clear in under a cycle, but the thermal element integrates over time for overloads.","metaTitle":"Siemens 3VM1063-3ED32-0AA0 SENTRON MCCB, 63 A, 3-Pole, TM210","metaDescription":"Siemens SENTRON 3VM1063-3ED32-0AA0 molded case circuit breaker, 63 A at 40 °C, 3-pole, TM210 release, 76 kA at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","title":"3VM1063-3ED32-0AA0","Height":"130 mm","Maximum":"630 A","Minimum":"1 s","at 240 V":"76 kA","at 415 V":"53 kA","at 440 V":"32 kA","at 500 V":"8 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","description":"circuit breaker 3VM1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=63A overload protection Ir=63A, not adjustable short-circuit protection Ii=10 x In nut keeper kit","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"22 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching capacity values in DC power systems, see the 3VA Molded Case Circuit Breaker Manual; link available under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"12 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front connection"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8639f3adb4318cd5c0a3c2fbb67e9acd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=575375&mlfb=3VM1063-3ED32-0AA0"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VM1063-3ED32-0AA0 at different voltages?","answer":"76 kA at 240 V AC, 53 kA at 415 V, 32 kA at 440 V, and 8 kA at 500 V. The 240 V and 415 V ratings are the ones most commonly used for industrial panel sizing."},{"question":"How does the 3VM1063-3ED32-0AA0 compare to the 3VA1110-5ED32-0AA0?","answer":"The 3VA1110-5ED32-0AA0 is a different series (3VA vs 3VM) with electronic overcurrent releases and communication options. The 3VM1063-3ED32-0AA0 uses a fixed TM210 thermal-magnetic release, no communication, and no ground-fault monitoring — it's a simpler, lower-cost line-protection breaker. Panel footprint differs; verify mounting dimensions before swapping."},{"question":"Where can I buy 3VM1063-3ED32-0AA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock count or lead-time number published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VM1063-3ED32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VM1063-3ED32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}