{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VM1110-4GE42-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VM1110-4GE42-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VM1110-4GE42-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VM1110-4GE42-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VM1110-4GE42-0AA0, 4-pole molded case circuit breaker, 100 A at 40 °C, TM220 thermal-magnetic release, line protection, 121 kA at 240 V.","salesMarkdown":"The Siemens 3VM1110-4GE42-0AA0 is a SENTRON 4-pole molded case circuit breaker (MCCB) rated for 100 A continuous at 40 °C, with a TM220 thermal-magnetic overcurrent release and line-protection designation. It carries a 121 kA interrupting capacity at 240 V AC — that figure drops to 76 kA at 415 V and 53 kA at 440 V, so the available fault current at the panelboard determines which voltage rating governs your application. Compared to the 3VA1010-2ED32-0AD0, the 3VM1110-4GE42-0AA0 is a different generation of the SENTRON platform. The 3VM series uses a TM220 release versus the 3VA's electronic options, and the 3VM carries a higher interrupting rating at 240 V (121 kA vs the 3VA's typical 65 kA range for similar amp frames). The 3VA series offers modular accessories like communication modules and voltage releases that the 3VM lacks — the 3VM has no communication function and no undervoltage release fitted. If your panel was specified around a 3VA1010, the 3VM1110 will occupy a similar footprint (70 mm deep, 101.6 mm wide, 130 mm tall) but the accessory slots and wiring scheme differ, so verify the termination kit and aux contact compatibility before swapping. The TM220 release is fixed thermal-magnetic, so no adjustment dials; trip settings are factory-set. No communication module, no voltage trigger, no ground-fault monitoring — it's a straight line-protection breaker. Derate the 100 A rating above 55 °C: 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, 91 A at 70 °C.","metaTitle":"Siemens 3VM1110-4GE42-0AA0 SENTRON MCCB, 100 A, 121 kA at 24","metaDescription":"Siemens SENTRON 3VM1110-4GE42-0AA0 molded case circuit breaker, 4-pole, 100 A rated at 40 °C, 121 kA interrupting at 240 V. TM220 release. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","title":"3VM1110-4GE42-0AA0","Height":"130 mm","at 240 V":"121 kA","at 415 V":"76 kA","at 440 V":"53 kA","at 500 V":"12 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","description":"circuit breaker 3VM1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=100A overload protection Ir=70A...100A short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit","Trip Indicator":"No","Number Of Poles":"4","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM220","Design Of Short-Circuit Protection":"For switching capacity values in DC power systems, see the 3VA Molded Case Circuit Breaker Manual; link available under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"100%","operating voltage / at AC / rated value":"690 V","Max. rated operational voltage Ue with DC":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Adjustable response value current / li max.":"1 000 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Max. rated operational voltage Ue with AC 50/60Hz":"500 V","Mechanical Service Life (Switching Cycles) / Typical":"15 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front connection","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3f0ee706be5ade96bbda51580efca6e9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=575396&mlfb=3VM1110-4GE42-0AA0"},"ai":{"faq":[{"question":"What is 3VM1110-4GE42-0AA0's interrupting capacity at 240 V?","answer":"121 kA at 240 V AC. At 415 V it's 76 kA, at 440 V it's 53 kA, and at 500 V it's 12 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VM1110-4GE42-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VM1110-4GE42-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}