{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VM1116-3GD42-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VM1116-3GD42-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VM1116-3GD42-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VM1116-3GD42-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VM1116-3GD42-0AA0, molded case circuit breaker, 4-pole, 160 A rated continuous current, TM210 thermal-magnetic release, breaking capacity 76 kA at 240 V AC, 53 kA at 415 V AC.","salesMarkdown":"## SENTRON 3VM1116-3GD42-0AA0 — 160 A Line Protection MCCB Its TM210 thermal-magnetic release provides fixed instantaneous and adjustable thermal protection, sized for the full 160 A rating — no derating needed at 40 °C, 45 °C, or 50 °C, where it holds the full 160 A. Breaking capacity runs 76 kA at 240 V AC, 53 kA at 415 V AC, and 32 kA at 440 V AC — enough for high-fault utility feeds without cascading upstream breakers. ## Thermal Performance and Panel Fit Dimensions are 70 mm deep, 101.6 mm wide, and 130 mm high — a compact 4-pole footprint that fits standard Siemens SENTRON distribution panel mounting. At 55 °C the breaker still carries 158 A, dropping to 150 A at 70 °C; the thermal curve means you can pack it into a warm enclosure without oversizing the frame. Maximum power loss is 38 W — factor that into enclosure ventilation when grouping several breakers. No direct functional replacement is needed at this lifecycle stage — the part is the active release.","metaTitle":"Siemens 3VM1116-3GD42-0AA0 SENTRON MCCB, 160 A, 4-Pole, 76 k","metaDescription":"Siemens 3VM1116-3GD42-0AA0 SENTRON molded case circuit breaker, 160 A rated, 4-pole, TM210 release, 76 kA at 240 V. Current lifecycle stage. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","title":"3VM1116-3GD42-0AA0","Height":"130 mm","at 240 V":"76 kA","at 415 V":"53 kA","at 440 V":"32 kA","at 500 V":"11.9 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.8 in","Width [In]":"4 in","Height [In]":"5.1 in","description":"circuit breaker 3VM1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A, not adjustable short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit","Number Of Poles":"4","Product version":"Line protection","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"38 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"160 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"690 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching capacity values in DC power systems, see the 3VA Molded Case Circuit Breaker Manual; link available under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"100%","reference code / acc. to IEC 81346-2":"Q","Max. rated operational voltage Ue with DC":"500 V","Product Extension / Optional / Motor Drive":"No","Adjustable response value current / lg min.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"1 600 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"500 V","Mechanical Service Life (Switching Cycles) / Typical":"12 000","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front connection","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6,5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3f0ee706be5ade96bbda51580efca6e9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=575425&mlfb=3VM1116-3GD42-0AA0"},"ai":{"faq":[{"question":"Does this breaker have a communication function?","answer":"No — the 3VM1116-3GD42-0AA0 is a standalone line protection MCCB without integrated communication."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VM1116-3GD42-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VM1116-3GD42-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}