{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VM1163-4ED22-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VM1163-4ED22-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VM1163-4ED22-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VM1163-4ED22-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VM1 series, molded case circuit breaker, 2-pole, 63 A (40-50 °C), 76 kA at 415 V AC, TM210 thermal-magnetic release, IP40 front.","salesMarkdown":"It carries a 63 A rating sustained from 40 °C through 50 °C, then derates to 58 A at 70 °C — the full thermal curve is in the spec table so you can size for a warm panel without guesswork. The TM210 thermal-magnetic release has an adjustable li of 630 A max, giving coordination headroom for motor feeders or transformer inrush. Dimensions are 70 mm deep, 50.8 mm wide, 130 mm tall — a standard 2-pole MCCB footprint that drops into most DIN-rail or bolt-on panel layouts without re-drilling. The 50.8 mm width matches the common 2-inch per-pole spacing used across SENTRON 3VM1 and 3VA families.","metaTitle":"Siemens 3VM1163-4ED22-0AA0 SENTRON MCCB, 63 A, 76 kA at 415","metaDescription":"Siemens 3VM1163-4ED22-0AA0 SENTRON molded case circuit breaker, 2-pole, 63 A rated at 40-50°C, 76 kA breaking at 415 V AC. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"50.8 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"76 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"2 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"2","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"500 V","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching capacity values in DC power systems, see the 3VA Molded Case Circuit Breaker Manual; link available under Service & Support in the last chapter","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"415 V","Max. rated operational voltage Ue with DC":"250 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Adjustable response value current / li max.":"630 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Max. rated operational voltage Ue with AC 50/60Hz":"415 V","Mechanical Service Life (Switching Cycles) / Typical":"15 000","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front connection"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/062f3aac021d2a63afaa57f8f1129f30.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=575091&mlfb=3VM1163-4ED22-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VM1163-4ED22-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VM1163-4ED22-0AA0 and how is it quoted?","answer":"It is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of this MCCB at different voltages?","answer":"At 240 V AC it interrupts 121 kA; at 415 V AC it interrupts 76 kA. The rated operational voltage is 415 V AC, with DC operation supported up to 250 V."},{"question":"What are the physical dimensions of 3VM1163-4ED22-0AA0?","answer":"Depth is 70 mm, width is 50.8 mm, height is 130 mm — a standard 2-pole MCCB footprint that fits existing SENTRON panel layouts."},{"question":"What type of overcurrent release does this breaker use?","answer":"It uses a TM210 thermal-magnetic release with an adjustable instantaneous trip current (li) up to 630 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VM1163-4ED22-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VM1163-4ED22-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}