{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"47298","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"47298","canonicalUrl":"https://aoctrl.com/schneider/47298","factsUrl":"https://aoctrl.com/api/mcp/products/47298","rawCanonicalId":null},"summary":{"shortDescription":"Control unit MicroLogic 6.0P, MasterPact NT drawout, selective and earth fault protections (LSIG), power meter","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Range":"MasterPact","Display type":"Digital display","Network type":"AC","Thermal memory":"20 mn","Trip unit name":"MicroLogic 6.0 P","Number of poles":"3P 4P","Protection type":"for overload protection (long time) for short time short-circuit protection for instantaneous short-circuit protection for earth fault","lifecycle_stage":"unknown","Local signalling":"3 LEDs (red) for electrical fault 1 LED (red) for internal error","Range of product":"MasterPact NT","Trip unit rating":"630 A at 50 °C 800 A at 50 °C 1000 A at 50 °C 1250 A at 50 °C 1600 A at 50 °C","Network frequency":"50/60 Hz","Device application":"Distribution","Type of measurement":"Power meter","Trip unit technology":"Electronic","Communication of data":"Measurement readout Protection and alarm settings Maintenance indicators","Earth-leakage protection":"Without","Product or component type":"Control unit","Protected poles description":"4t 3t 3t + N/2","Circuit breaker mounting mode":"Drawout","Trip unit protection functions":"Selective + earth-fault protection","Zone selective interlocking ZSI":"With","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable 9 settings","Short-time protection delay adjustment type tsd":"Adjustable","[Tr] Long-Time Protection Delay Adjustment Range":"0.7...16.6 s at 7.2 x Ir 0.7...24 s at 6 x Ir 12.5...600 s at 1.5 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"0.4...1 x In","[tsd] Short-time protection delay adjustment range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Instantaneous protection pick-up adjustment type Ii":"Adjustable 9 settings","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.2...1 x In for 400 A < In < 1250 A 0.3...1 x In for In 500...1200 A for In >= 1250 A","[Ii] instantaneous protection pick-up adjustment range":"2...15 x In Off","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,857.21","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e21a1231720386637ced2d0c6f82b4ae.pdf","sourceUrl":"https://www.se.com/ie/en/product/47298/control-unit-micrologic-6-0p-masterpact-nt-drawout-selective-and-earth-fault-protections-lsig-power-meter/","alternativesUrl":"https://aoctrl.com/api/mcp/products/47298/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/47298","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/47298 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}