{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"48367","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"48367","canonicalUrl":"https://aoctrl.com/schneider/48367","factsUrl":"https://aoctrl.com/api/mcp/products/48367","rawCanonicalId":null},"summary":{"shortDescription":"Control unit MicroLogic 6.0H, MasterPact NW drawout, selective and earth fault protections (LSIG), power meter+harmonics","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Range":"MasterPact","Display type":"Digital display","Network type":"AC","Thermal memory":"20 mn","Trip unit name":"MicroLogic 6.0 H","Number of poles":"3P 4P","Protection type":"for overload protection (long time) for short time short-circuit protection for instantaneous short-circuit protection for earth fault","lifecycle_stage":"unknown","Local signalling":"3 LEDs (red) for electrical fault 1 LED (red) for internal error","Range of product":"MasterPact NW","Trip unit rating":"800 A at 50 °C 1000 A at 50 °C 1250 A at 50 °C 1600 A at 50 °C 2000 A at 50 °C 2500 A at 50 °C 3200 A at 50 °C 4000 A at 50 °C 5000 A at 50 °C 6300 A at 50 °C","Network frequency":"50/60 Hz","Device application":"Distribution","Type of measurement":"Harmonics meter Power meter","Trip unit technology":"Electronic","Communication of data":"Measurement readout Protection and alarm settings Maintenance indicators","Earth-leakage protection":"Without","Product or component type":"Control unit","Protected poles description":"4t 3t 3t + N/2","Circuit breaker mounting mode":"Drawout","Trip unit protection functions":"Selective + earth-fault protection","Zone selective interlocking ZSI":"With","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable 9 settings","Short-time protection delay adjustment type tsd":"Adjustable","[Tr] Long-Time Protection Delay Adjustment Range":"0.7...16.6 s at 7.2 x Ir 0.7...24 s at 6 x Ir 12.5...600 s at 1.5 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"0.4...1 x In","[tsd] Short-time protection delay adjustment range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Instantaneous protection pick-up adjustment type Ii":"Adjustable 9 settings","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.2...1 x In for 400 A < In < 1250 A 0.3...1 x In for In 500...1200 A for In >= 1250 A","[Ii] instantaneous protection pick-up adjustment range":"Off 2...15 x In","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,712.61","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9a7039912a4f996b18270e66af7bd20d.pdf","sourceUrl":"https://www.se.com/ie/en/product/48367/control-unit-micrologic-6-0h-masterpact-nw-drawout-selective-and-earth-fault-protections-lsig-power-meter+harmonics/","alternativesUrl":"https://aoctrl.com/api/mcp/products/48367/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/48367","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/48367 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}