{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"48735","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"48735","canonicalUrl":"https://aoctrl.com/schneider/48735","factsUrl":"https://aoctrl.com/api/mcp/products/48735","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker frame, MasterPact NW08H10, 800A, 50kA/1150VAC 50/60Hz (Icu), 4 poles, drawout, without control unit","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"MasterPacT","Width":"556 mm","Height":"439 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPact NW","Mounting mode":"Drawout","Sensor rating":"400 A 800 A","lifecycle_stage":"unknown","Connection pitch":"115 mm","Mounting support":"Backplate Rails","Neutral position":"Left","Performance type":"H10 50 kA 1150 V AC","Pollution degree":"3 conforming to IEC 60664-1","Poles description":"4P","Upside connection":"Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"800 A at 40 °C","Downside connection":"Rear","Circuit breaker name":"MasterPact NW08H10","Selectivity category":"Category B","Electrical durability":"500 cycles 1150 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"12500 cycles without maintenance 25000 cycles with maintenance","IP degree of protection":"IP30 conforming to IEC 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1250 V AC 50/60 Hz","[Ue] rated operational voltage":"1150 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"50 kA at 1150 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"50 kA 1 s 50 kA 3 s","[Icm] rated short-circuit making capacity":"105 kA 1150 V AC at 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"50 kA at 1150 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,660.48","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/318dd2beae5165688f4a50e823daa67b.pdf","sourceUrl":"https://www.se.com/au/en/product/48735/circuit-breaker-frame-masterpact-nw08h10-800a-50ka-1150vac-50-60hz-icu-4-poles-drawout-without-control-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/48735/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/48735","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/48735 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}