{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"4EU2452-0EL00-0EA0","brand":"Siemens","brandSlug":"siemens","productSlug":"4EU2452-0EL00-0EA0","canonicalUrl":"https://aoctrl.com/siemens/4EU2452-0EL00-0EA0","factsUrl":"https://aoctrl.com/api/mcp/products/4EU2452-0EL00-0EA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIDAC output reactor, 3-phase, 21 A, 8000 Hz rated switching frequency, 0.2 mH, IP05, thermal class H, free cable endings.","salesMarkdown":"It's sized for AC motor drives where the inverter output needs a choke to limit dv/dt and smooth the current waveform to the motor windings — common on VFD-fed conveyor, pump, or fan lines. The 0.2 mH inductance and 7.7 % impedance (per EN 61558-2-20) are matched to a 460 V AC system. The 21 A maximum current is the thermal limit at 40 °C ambient with class H insulation (180 °C rated). That means it can sit in a warm panel — up to 40 °C — without derating, and the class H winding gives headroom for overloads that would cook a class B or F reactor. The 8000 Hz switching frequency matches modern IGBT drives running 4–8 kHz PWM; if your drive runs at 2 kHz or 16 kHz, this reactor still works but the core losses shift — the 8 kHz rating is the design point for lowest loss. IP05 means it's open-frame with basic drip protection — it's for indoor panel mounting, not washdown or outdoor. The free cable endings (no terminals) mean you land the motor leads directly onto the reactor pigtails inside the enclosure. Plan for a cable gland or strain relief at the panel entry.","metaTitle":"Siemens SIDAC 4EU2452-0EL00-0EA0 Output Reactor, 21A, 3-Phas","metaDescription":"Siemens SIDAC output reactor, 3-phase, 21A, 8kHz switching frequency, 0.2mH, IP05, thermal class H. Mature lifecycle. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"0.13 m","Width":"0.22 m","Height":"0.21 m","IP Rating":"IP05","Product Status":"Mature"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=489657&mlfb=4EU2452-0EL00-0EA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/4EU2452-0EL00-0EA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/4EU2452-0EL00-0EA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/4EU2452-0EL00-0EA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}