{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"4EU3022-6BA00-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"4EU3022-6BA00-0AA0","canonicalUrl":"https://aoctrl.com/siemens/4EU3022-6BA00-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/4EU3022-6BA00-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 4EU3022-6BA00-0AA0 commutating choke for converter, 3-phase, AC, 315A AC max, 500V, 50Hz, IP00, 0.211m depth, 0.3m width, 0.269m height.","salesMarkdown":"## What This Choke Does in Your Converter Line The Siemens 4EU3022-6BA00-0AA0 is a 3-phase commutating choke rated for converter duty — it limits the rate of current rise (di/dt) during thyristor commutation, protecting the converter's semiconductors from overcurrent stress. The 315 A AC maximum current (at 50 Hz, 500 V) and 283.5 A AC rated operational current tell you the continuous load it can carry in a 40 °C ambient; push past that and the thermal class H insulation (IEC 60085) gives you a 180 °C hot-spot ceiling before the winding degrades. The 0.000087 H inductance with a 4 % relative inductive voltage drop is sized to keep commutation notches within the converter's tolerance — too low and the thyristors see a current spike, too high and the voltage drop eats into your DC bus. ## Mounting and Integration — IP00 Means an Enclosure IP00 protection class means the choke has no housing — the windings and core are exposed. The flat-type terminals accept busbar or cable lugs; plan for a bolted connection rather than a spring-clamp. Footprint is 0.3 m wide by 0.269 m tall by 0.211 m deep. The 220 W coil loss plus 110 W iron core loss total 330 W of heat to vent — factor that into your cabinet's thermal budget or you'll cook the 40 °C ambient rating.","metaTitle":"Siemens 4EU3022-6BA00-0AA0 Commutating Choke, 315A AC, 500V,","metaDescription":"Siemens 4EU3022-6BA00-0AA0 commutating choke for converter, 3-phase, 315A AC max, 500V, 50Hz, IP00, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Line/Load Reactors"],"specifications":{"Depth":"0.211m","Width":"0.3m","Height":"0.269m","Peak Current":"394A","Phase Number":"3","Type Of Voltage":"AC","lifecycle_stage":"mature","Product Designation":"Kommut.-Drossel f. Stromrichter","protection class IP":"IP00","current at AC maximum":"315A","Inductivity Rated Value":"0.000087H","current at DC rated value":"386A","power loss [W] of the coil":"220W","Operating Voltage Rated Value":"500V","Ambient Temperature Rated Value":"40°C","Operating Frequency Rated Value":"50Hz","power loss [W] of the iron core":"110W","thermal class according to IEC 60085":"H","operational current at AC rated value":"283.5A","Type Of Electrical Connection For Main Current Circuit":"flat connector","Relative Inductive Drop In Voltage For Rated Value Of The Current, Voltage And Frequency":"4%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/91d6efa6a8344ec29874ff1eaf097ebc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=366426&mlfb=4EU3022-6BA00-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/4EU3022-6BA00-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is 4EU3022-6BA00-0AA0's listed depth?","answer":"The depth is 0.211 m."},{"question":"What is 4EU3022-6BA00-0AA0's listed width?","answer":"The width is 0.3 m."},{"question":"Where can I buy 4EU3022-6BA00-0AA0 and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send your target quantity for a firm price."},{"question":"Will 4EU3022-6BA00-0AA0 drop into a panel specified around 5SJ3140-7 without rewiring?","answer":"No — the 5SJ3140-7 is a 1-pole 40 A miniature circuit breaker (MCB) with IP20 and a 240 V AC rating, not a commutating choke. They serve completely different functions; no drop-in substitution is possible."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/4EU3022-6BA00-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/4EU3022-6BA00-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}