{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"4EU3632-5MA08-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"4EU3632-5MA08-0AA0","canonicalUrl":"https://aoctrl.com/siemens/4EU3632-5MA08-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/4EU3632-5MA08-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIDAC series, 3-phase filter reactor, order code 4EU3632-5MA08-0AA0, rated 83.1 A / max 92.3 A, 400 V AC, 50 Hz, 60 kvar, IP00.","salesMarkdown":"The Siemens SIDAC 4EU3632-5MA08-0AA0 is a 3-phase filter reactor — a line reactor with a specific detuning ratio — designed to sit between a variable-frequency drive and the mains, or in a harmonic-filter bank, to suppress current harmonics and limit inrush. It's rated for a continuous 83.1 A with a maximum of 92.3 A, on a 400 V, 50 Hz supply, and delivers 60 kvar of reactive power. The 14% relative throttling factor (p=14%) and 1.4 mH inductance are tuned to a 134 Hz resonant frequency, which means it's typically used in a detuned filter bank to block the 5th and 7th harmonics from propagating back onto the line. The 83.1 A rated current and 92.3 A maximum set the thermal limit for continuous motor or drive load. If your drive's input current exceeds 92.3 A at full load, this reactor will saturate or overheat — size up. The 400 V, 50 Hz rating is standard for European industrial mains; it will not work on a 480 V, 60 Hz line without derating the core. The 365 W power loss at rated load means the reactor dissipates that heat into the panel — IP00 open-frame construction (no enclosure) requires free air circulation or forced ventilation in the cabinet. The 0.227 m depth, 0.35 m width, and 0.321 m height define the footprint; it mounts via the flat-type screw terminals on the main circuit, not on a DIN rail. Class H insulation (180 °C thermal class per IEC 60085) gives headroom for a 40 °C ambient — the reactor can run hot without winding failure, but the surrounding components must tolerate the radiated heat.","metaTitle":"Siemens SIDAC 4EU3632-5MA08-0AA0 Filter Reactor, 83.1 A, 400","metaDescription":"Siemens SIDAC 4EU3632-5MA08-0AA0 3-phase filter reactor, rated 83.1 A / 92.3 A max, 400 V, 50 Hz, 60 kvar, IP00. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Line/Load Reactors"],"specifications":{"Depth":"0.227m","Width":"0.35m","Height":"0.321m","Maximum":"92.3A","Rated Value":"83.1A","Phase number":"3","Power loss [W]":"365W","Type of voltage":"AC","lifecycle_stage":"mature","Product brand name":"SIDAC","Product designation":"filter reactor","Protection class IP":"IP00","Inductivity rated value":"0.0014H","Relative throttling factor":"14%","Operating voltage rated value":"400V","Ambient temperature rated value":"40°C","Operating frequency rated value":"50Hz","Thermal class acc. to IEC 60085":"H","Resonant frequency of the filter":"134Hz","Reactive power of the filter bank rated value":"60 000var","Type of electrical connection for main current circuit":"flat connector / screw-type terminals"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=62487&mlfb=4EU3632-5MA08-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/4EU3632-5MA08-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 4EU3632-5MA08-0AA0?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time."},{"question":"What is the physical size of 4EU3632-5MA08-0AA0?","answer":"The dimensions are 0.227 m depth, 0.35 m width, and 0.321 m height. It is an open-frame (IP00) component with flat-type screw terminals for the main circuit connection."},{"question":"What compliance documentation does this Siemens SIDAC reactor carry?","answer":"The part is designed to EN 61558-2-20 (safety of transformers, reactors, and power supply units). The insulation class is H per IEC 60085. No UL, CSA, or specific RoHS/REACH declarations are in the record — verify with the manufacturer for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/4EU3632-5MA08-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/4EU3632-5MA08-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}