{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"4EU3652-6UB00-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"4EU3652-6UB00-0AA0","canonicalUrl":"https://aoctrl.com/siemens/4EU3652-6UB00-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/4EU3652-6UB00-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 4EU3652-6UB00-0AA0 mains choke (line reactor) for variable-frequency drives, 3-phase, 500 V AC, 360 A rated current, 0.091 mH, 4 % voltage drop, IP00, flat-type terminals, UL/CSA recognized.","salesMarkdown":"## What this mains choke does for a VFD line The Siemens 4EU3652-6UB00-0AA0 is a three-phase mains choke — a line reactor — sized for the input of a variable-frequency drive (Netzdrossel f. FU). Its job is to limit harmonic distortion, smooth line-side current spikes, and protect the drive's rectifier from grid-borne transients. Rated for 360 A continuous with a 400 A maximum, it sits upstream of the VFD in a 500 V AC, 50 Hz system. The 0.091 mH inductance and 4 % relative inductive voltage drop are the key numbers for sizing: that drop tells you how much voltage the choke consumes at rated current, which you need to budget in the drive's input voltage margin. The 360 A rated current (I LN) and 400 A maximum (Ithmax) define the thermal envelope: the choke can carry 360 A continuously in a 40 °C ambient without exceeding Class H (180 °C) insulation temperature rise. Total copper loss is 300 W, iron-core loss 135 W — that heat must be shed. IP00 means no enclosure; the choke is an open-frame component intended for mounting inside a ventilated panel or drive cabinet. UL and CSA recognition per EN 61558-2-20 is noted in the description — a signal for North American panel shops that the component meets transformer / reactor safety standards. The choke measures 0.35 m wide by 0.321 m tall by 0.237 m deep — roughly 14 × 12.6 × 9.3 inches. That is a substantial block; verify panel door clearance and mounting plate space before committing. The flat-type terminals call for bus-bar or compression-lug connections, not ring-tongue terminals on small-gauge wire. IP00 means no drip shield — keep it above any potential condensation path or dripping cable glands in the enclosure.","metaTitle":"Siemens 4EU3652-6UB00-0AA0 Mains Choke, 360 A, 0.091 mH, IP0","metaDescription":"Siemens 4EU3652-6UB00-0AA0 mains choke for VFD, 3-phase, 500 V AC, 360 A rated, 0.091 mH, 4% voltage drop, IP00, UL/CSA recognized. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Line/Load Reactors"],"specifications":{"Depth":"0.237m","Width":"0.35m","Height":"0.321m","Maximum":"400A","Rated Value":"360A","Phase number":"3","Type of voltage":"AC","lifecycle_stage":"mature","Product designation":"Netzdrossel f. FU","Protection class IP":"IP00","Inductivity rated value":"0.000091H","Power loss [W] of the coil":"300W","Operating voltage rated value":"500V","Ambient temperature rated value":"40°C","Operating frequency rated value":"50Hz","Power loss [W] of the iron core":"135W","Thermal class acc. to IEC 60085":"H","Type of electrical connection for main current circuit":"flat connector","Relative inductive drop in voltage on the measurement level current, voltage and frequency":"4%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=7432&mlfb=4EU3652-6UB00-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/4EU3652-6UB00-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 4EU3652-6UB00-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What are the key electrical ratings for 4EU3652-6UB00-0AA0?","answer":"Rated current 360 A, maximum current 400 A, rated voltage 500 V AC, 50 Hz, inductance 0.091 mH, 4 % inductive voltage drop at rated current. Three-phase, IP00 open-frame construction with flat-type terminals."},{"question":"What compliance documentation is available for 4EU3652-6UB00-0AA0?","answer":"The part is UL and CSA recognized per EN 61558-2-20. No RoHS or REACH declaration is explicitly listed in the record, but the mature Siemens product line typically supplies those on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/4EU3652-6UB00-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/4EU3652-6UB00-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}