{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"56132","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"56132","canonicalUrl":"https://aoctrl.com/schneider/56132","factsUrl":"https://aoctrl.com/api/mcp/products/56132","rawCanonicalId":null},"summary":{"shortDescription":"Residual current protection relay, VigiPacT RH10M, 100mA, 220/240VAC 50/60Hz, DIN rail mounting","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"74 mm","Range":"VigiPacT","Reset":"Manual reset","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2 Annex M EN/IEC 60755 UL 1053 CAN/CSA C22.2 No. 144","Monitoring":"Electronics (continuous) Power supply (continuous) Relay/sensor link (continuous)","9 Mm Pitches":"6","Minimum load":"10 mA at 12 V","Test function":"Remote test Local","Product weight":"0.3 kg","Earthing system":"IT TT TN-S","lifecycle_stage":"unknown","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60664-1","Device short name":"RH10M","Relative humidity":"95 % at 55 °C","Relay application":"Protection relay","Tightening torque":"Auxiliary power supply: 0.6 N.m top Fault: 0.6 N.m bottom Relay test and fault reset: 0.25 N.m bottom Sensor: 0.25 N.m top Voltage presence: 0.6 N.m bottom","Type of measurement":"Earth fault current internal measurement, range: 80...100 %","Overvoltage category":"IV","Mechanical robustness":"Fire resistance conforming to IEC 60695-2-1 IK protection 2 joules: IK07 conforming to EN 50102 Vibrations 13.2...100 Hz: 0.7 g Vibrations 2...13.2 Hz: +/- 1 mm","Wire stripping length":"Auxiliary power supply: 7 mm for top connection Fault: 8 mm for bottom connection Relay test and fault reset: 5 mm for bottom connection Sensor: 5 mm for top connection Voltage presence: 8 mm for bottom connection","Connections - terminals":"Auxiliary power supply: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12 Auxiliary power supply: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12 Auxiliary power supply: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12 Fault: screw terminal cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12 Fault: screw terminal cable(s) 0.2...4 mm² rigid AWG 24...AWG 12 Fault: screw terminal cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12 Relay test and fault reset: screw terminal cable(s) 0.14...1 mm² flexible AWG 26...AWG 16 Relay test and fault reset: screw terminal cable(s) 0.14...1.5 mm² rigid AWG 26...AWG 16 Relay test and fault reset: screw terminal cable(s) 0.25...0.5 mm² flexible AWG 26...AWG 16 Sensor: screw terminal cable(s) 0.14...1 mm² flexible AWG 26...AWG 16 Sensor: screw terminal cable(s) 0.14...1.5 mm² rigid AWG 26...AWG 16 Sensor: screw terminal cable(s) 0.25...0.5 mm² flexible AWG 26...AWG 16 Voltage presence: screw terminal cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12 Voltage presence: screw terminal cable(s) 0.2...4 mm² rigid AWG 24...AWG 12 Voltage presence: screw terminal cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529","Power consumption in VA":"4 VA","Tamperproof of settings":"Protected by sealable cover","Earth-leakage time delay":"Instantaneous","Earth-leakage sensitivity":"0.1 A","Product or component type":"Residual current protection relay","[Us] rated supply voltage":"220...240 V AC 50/60 Hz 55...110 %","Current sensors compatibility":"VigiPacT TOA earth leakage current sensor VigiPacT A earth leakage current sensor VigiPacT L earth leakage current sensor","Electromagnetic compatibility":"Conducted and radiated emissions: , B, conforming to CISPR 11 Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6 Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2 High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5 Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4 Radiated susceptibility: , 3, conforming to IEC 61000-4-3","Monitored distribution system":"1000 V - AC at 50/60 Hz (maximum) 1000 V - AC at 400 Hz (maximum)","Earth-leakage protection class":"Type A","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-55...85 °C","Ambient air temperature for operation":"-35...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ithe] conventional enclosed thermal current":"8 A","Residual earth-leakage sensitity adjustment type":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1cc814be4e47a800ebb4e593dc498665.pdf","sourceUrl":"https://www.se.com/ie/en/product/56132/residual-current-protection-relay-vigipact-rh10m-100ma-220-240vac-50-60hz-din-rail-mounting/","alternativesUrl":"https://aoctrl.com/api/mcp/products/56132/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/56132","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/56132 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}