{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"56170","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"56170","canonicalUrl":"https://aoctrl.com/schneider/56170","factsUrl":"https://aoctrl.com/api/mcp/products/56170","rawCanonicalId":null},"summary":{"shortDescription":"Residual current protection relay, VigiPacT RH99M, 30mA-30A, 12/24VAC 50/60Hz, 12/48VDC, DIN rail mounting","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"2.9 in (74 mm)","Range":"VigiPacT","Reset":"Manual reset","Width":"2.1 in (54 mm)","Height":"3.2 in (81 mm)","Category":"00992-UL VIGIREX GROUND FAULT RELAY & SENSOR","Standards":"EN/IEC 60947-2 Annex M EN/IEC 60755 UL 1053 CAN/CSA C22.2 No. 144","Monitoring":"Electronics continuous) Power supply continuous) Relay/sensor link continuous)","9 Mm Pitches":"6","Minimum load":"10 mA 12 V","Test function":"Remote test Local","Earthing system":"TN-S IT TT","Type of setting":"Selector","lifecycle_stage":"unknown","Mounting Support":"DIN rail","Pollution degree":"3 IEC 60664-1","Device short name":"RH99M","Relative humidity":"95 % 131 °F (55 °C)","Relay application":"Protection relay","Tightening torque":"Auxiliary power supply: 5.3 lbf.in (0.6 N.m) top Fault: 5.3 lbf.in (0.6 N.m) bottom Relay test and fault reset: 2.21 lbf.in (0.25 N.m) bottom Sensor: 2.21 lbf.in (0.25 N.m) top Voltage presence: 5.3 lbf.in (0.6 N.m) bottom","Type of measurement":"Earth fault current internal measurement 80...100 %","Overvoltage category":"IV","Mechanical robustness":"Fire resistance IEC 60695-2-1 IK protection 2 joulesIK07 EN 50102 Vibrations 13.2...100 Hz0.7 g Vibrations 2...13.2 Hz+/- 1 mm","Nbr. of units in pkg.":"1","Wire stripping length":"Auxiliary power supply: 0.3 in (7 mm) for top connection Fault: 0.3 in (8 mm) for bottom connection Relay test and fault reset: 0.2 in (5 mm) for bottom connection Sensor: 0.2 in (5 mm) for top connection Voltage presence: 0.3 in (8 mm) for bottom connection","Connections - terminals":"Auxiliary power supply terminal block 0.0003...0.004 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12 Auxiliary power supply terminal block 0.0003...0.004 in² (0.2...2.5 mm²) rigid AWG 24...AWG 12 Auxiliary power supply terminal block 0.0004...0.004 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12 Fault screw terminal 0.0003...0.004 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12 Fault screw terminal 0.0003...0.006 in² (0.2...4 mm²) rigid AWG 24...AWG 12 Fault screw terminal 0.0004...0.004 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset screw terminal 0.0002...0.002 in² (0.14...1 mm²) flexible AWG 26...AWG 16 Relay test and fault reset screw terminal 0.0002...0.002 in² (0.14...1.5 mm²) rigid AWG 26...AWG 16 Relay test and fault reset screw terminal 0.0004...0.0008 in² (0.25...0.5 mm²) flexible AWG 26...AWG 16 Sensor screw terminal 0.0002...0.002 in² (0.14...1 mm²) flexible AWG 26...AWG 16 Sensor screw terminal 0.0002...0.002 in² (0.14...1.5 mm²) rigid AWG 26...AWG 16 Sensor screw terminal 0.0004...0.0008 in² (0.25...0.5 mm²) flexible AWG 26...AWG 16 Voltage presence screw terminal 0.0003...0.004 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12 Voltage presence screw terminal 0.0003...0.006 in² (0.2...4 mm²) rigid AWG 24...AWG 12 Voltage presence screw terminal 0.0004...0.004 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529","Power consumption in VA":"4 VA","Tamperproof of settings":"Protected by sealable cover","Earth-leakage time delay":"Instantaneous for 0.03 A Adjustable 9 settings 0...4.5 s for 0.03...30 A","Earth-leakage sensitivity":"0.03...30 A","Product or Component Type":"Residual current protection relay","[Us] rated supply voltage":"12...24 V AC 50/60 Hz 55...120 % 12...48 V DC 55...120 %","Current sensors compatibility":"VigiPacT TOA earth leakage current sensor VigiPacT A earth leakage current sensor VigiPacT L earth leakage current sensor","Electromagnetic compatibility":"Conducted and radiated emissionsB CISPR 11 Conducted radio-frequency immunity test3 IEC 61000-4-6 Electrostatic discharge immunity test4 IEC 61000-4-2 High-energy conducted susceptibility4 IEC 61000-4-5 Low-energy conducted susceptibility4 IEC 61000-4-4 Radiated susceptibility3 IEC 61000-4-3","Monitored distribution system":"1000 V - AC 50/60 Hz maximum) 1000 V - AC 400 Hz maximum)","Earth-leakage protection class":"Type A","Electrical shock protection class":"Class II","Ambient Air Temperature for Storage":"-67...185 °F (-55...85 °C)","Ambient Air Temperature for Operation":"-31...158 °F (-35...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Ithe] conventional enclosed thermal current":"8 A","Residual earth-leakage sensitity adjustment type":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$179.07","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4540e67262c924f88d7c0c8453960f7f.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/56170/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/56170","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/56170 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}