{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SJ3610-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SJ3610-7","canonicalUrl":"https://aoctrl.com/siemens/5SJ3610-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SJ3610-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SJ3 miniature circuit breaker, 3P+N, C-curve, 10 A, 4.5 kA breaking capacity, 400 V AC, 4 MW units, IP20.","salesMarkdown":"The Siemens 5SJ3610-7 is a 3P+N SENTRON 5SJ3 miniature circuit breaker with a C-curve trip characteristic rated at 10 A and a breaking capacity of 4.5 kA per both EN 60898 and IEC 60947-2. It occupies 4 width units (70 mm installation depth) on the DIN rail and accepts solid or stranded conductors from 0.75 to 25 mm². At 10 A it's sized for lighting, small power, or control transformer feeds in a 400 V AC three-phase panel. The 4.5 kA breaking capacity at 400 V AC (EN 60898 / IEC 60947-2) is the standard domestic and light-commercial rating. In a panel with a 10 kA upstream device you get full selectivity up to about 3 kA; above that the MCB and upstream breaker may both open. If your fault-current study shows prospective short-circuit current above 4.5 kA at the panelboard, step up to the 5SL4 series (10 kA) — but that means a different footprint and terminal layout. ## Panel integration The 70 mm depth fits flush in a 4-module-wide cutout. Ambient temperature range is -20 to +45 °C, with periodic excursions to +55 °C at up to 95% humidity. The 20 000 mechanical switching cycles cover normal switching plus occasional fault clearing over the panel's service life.","metaTitle":"Siemens 5SJ3610-7 SENTRON MCB, 3P+N, C-10A, 4.5kA","metaDescription":"Siemens 5SJ3610-7 SENTRON miniature circuit breaker, 3P+N, C-curve 10 A, 4.5 kA breaking capacity per EN 60898/IEC 60947-2. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Solid":"0.75 ... 25 mm²","Sealable":"Yes","Stranded":"0.75 ... 25 mm²","Rated Value":"50 Hz","Halogen-Free":"Yes","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"4","Type of voltage":"AC/DC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-20 ... +45 °C","Product designation":"Miniature circuit breakers","Protection class IP":"IP20, with connected conductors","Overvoltage category":"3","Design of the product":"Miniature circuit breaker 5SJ3","Energy limiting class":"3","Number of width units":"4","Number of poles / Note":"3P+N","circuit-breaker / Design":"5SJ3","Current / at AC / rated value":"10 A","Tripping characteristic class":"C","at DC / rated value / maximum":"60 V","acc. to EN 60898 / rated value":"4.5 kA","Position / of power supply cord":"Any","acc. to IEC 60947-2 / rated value":"4.5 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"400 V","Influence of the surrounding temperature":"Periodically +55°C, max. 95% humidity","Insulation voltage / at AC / rated value":"440 V","Vibration resistance / acc. to IEC 60068-2-6":"50m/s² at 25 to 150Hz and 60m/s² at 10 to 150 Hz","with multi-phase operation / at AC / maximum":"440 V","Mechanical service life (switching cycles) / typical":"20 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=74756&mlfb=5SJ3610-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SJ3610-7/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 5SJ3610-7 and get a price?","answer":"The 5SJ3610-7 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the solid conductor range for the 5SJ3610-7?","answer":"The 5SJ3610-7 accepts solid conductors from 0.75 to 25 mm², and stranded conductors in the same range."},{"question":"Will the 5SJ3610-7 drop into a panel specified around the 5SL4120-7CC?","answer":"No — the 5SJ3610-7 is a 3P+N 10 A unit occupying 4 width units (70 mm depth), while the 5SL4120-7CC is a 1P 20 A unit in 1 width unit. The footprint, pole count, and current rating are different; rewiring and DIN-rail space reallocation are required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SJ3610-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SJ3610-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}