{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SJ4213-7HG41","brand":"Siemens","brandSlug":"siemens","productSlug":"5SJ4213-7HG41","canonicalUrl":"https://aoctrl.com/siemens/5SJ4213-7HG41","factsUrl":"https://aoctrl.com/api/mcp/products/5SJ4213-7HG41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SJ4 series, miniature circuit breaker, order code 5SJ4213-7HG41, 2-pole, C characteristic, 10 kA (EN 60898), 15 kA (IEC 60947-2), 400 V AC rated, 70 mm depth, 36 mm width.","salesMarkdown":"The Siemens 5SJ4213-7HG41 is a 2-pole miniature circuit breaker from the SENTRON 5SJ4 series, rated for 400 V AC and 60 V DC, with a C tripping characteristic. ## DIN-rail fit and panel integration Depth is 70 mm, so it clears a standard 80 mm enclosure backwall with 10 mm to spare for wiring. ## What the C-curve means in practice It's not for high-inrush loads (D-curve territory) nor purely resistive circuits (B-curve). Rated for 50 Hz supply. Vibration resistance to 50 m/s² at 25–150 Hz and 60 m/s² at 35 Hz (4 sec) means it holds up on a machine frame or conveyor line. Rated for mechanical engineering and industry use per the manufacturer's suitability classification. EMC environment B (immunity not applicable) — no special filtering required for the breaker itself, but the load side may still need it.","metaTitle":"Siemens 5SJ4213-7HG41 SENTRON MCB, 2-Pole C-Curve 10kA","metaDescription":"Siemens 5SJ4213-7HG41 SENTRON miniature circuit breaker, 2-pole, C characteristic, 10 kA per EN 60898, 15 kA per IEC 60947-2. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SJ4213-7HG41","Height":"110 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 240 V 14kA, 2-pole, C, 13 A, D=70 mm according to UL 489","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"on standard mounting rail","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breakers","protection class IP":"IP20, with connected conductors, IP 40 in the handle range","Overvoltage Category":"3","Tunnel Terminals Top":"No","Vibration Resistance":"50 m/s² at 25 to 150Hz and 60m/s² at 35Hz (4sec)","Combined Terminal Top":"Yes","Design Of The Product":"Miniature circuit-breaker 5SJ4","Product Function Note":"Terminal tightening torque for Cu, 60/75°C; 3.5Nm/31lb.in","Tunnel Terminals Bottom":"No","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","at DC rated value maximum":"60 V","Neutral Conductor Switching":"No","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"10 kA","Ambient Temperature During Operation":"max. 95% humidity","Supply Voltage Frequency Rated Value":"50 Hz","according to IEC 60947-2 rated value":"15 kA","installation environment regarding EMC":"Suitable for environment B (immunity to interference not applicable)","insulation voltage (Ui) at AC rated value":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"±1 mm at 5 to 25 Hz; 50 m/s² at 25 to 150 Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Tightening Torque With Screw-Type Terminals Maximum":"3.5 N·m","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/04154521c86e2b8ba2dbfd060e129d32.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=292847&mlfb=5SJ4213-7HG41"},"ai":{"faq":[{"question":"Where can I buy 5SJ4213-7HG41 and get a price?","answer":"This part is sourced and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"Will 5SJ4213-7HG41 drop into a panel specified around 5SY4140-7 without rewiring?","answer":"Both are 2-pole C-curve MCBs on the same DIN-rail footprint, but the 5SY series typically has different breaking capacity and terminal design. The 5SJ4213-7HG41 uses combined terminals (box + tunnel) at 3.5 Nm torque; verify the existing wiring's ferrule type and conductor cross-section before swapping — the terminal style may require a different strip length or ferrule."},{"question":"What is the 5SJ4213-7HG41's depth?","answer":"Depth is 70 mm, matching the installation depth. It fits standard 80 mm deep enclosures with 10 mm clearance behind the DIN rail."},{"question":"What compliance documentation does Siemens provide for this MCB?","answer":"The part is halogen-free and silicon-free. It carries ratings per EN 60898 (10 kA) and IEC 60947-2 (15 kA), which implies CE marking for the European market. Specific RoHS, REACH, or UL documentation should be confirmed at order time — the evidence does not list those certifications explicitly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SJ4213-7HG41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SJ4213-7HG41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}