{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SJ4216-7HG41","brand":"Siemens","brandSlug":"siemens","productSlug":"5SJ4216-7HG41","canonicalUrl":"https://aoctrl.com/siemens/5SJ4216-7HG41","factsUrl":"https://aoctrl.com/api/mcp/products/5SJ4216-7HG41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SJ4 series, 2-pole miniature circuit breaker, C-curve, 10 kA interrupting capacity per EN 60898, 15 kA per IEC 60947-2, 400 V AC / 60 V DC.","salesMarkdown":"## Panel fit and DIN-rail integration The Siemens 5SJ4216-7HG41 is a 2-pole miniature circuit breaker from the SENTRON 5SJ4 series, occupying 2 modular width units (36 mm) on a standard DIN rail. ## Breaking capacity and trip curve Rated 10 kA per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC, this C-curve breaker handles moderate inrush from motor starters and transformer banks without nuisance tripping. On the DC side, the rating drops to 60 V — sufficient for control-circuit isolation in a 48 VDC panel but not for a 125 VDC battery bank. The overvoltage category is 3, and the pollution degree is 3, matching the environment inside an unsealed industrial enclosure. The SENTRON 5SJ4 series is the established line for European-spec panel builds. If your BOM calls for a UL 489-listed equivalent, note that this breaker carries EN/IEC approvals (EN 60898, IEC 60947-2) — verify the project's listing requirements before specifying.","metaTitle":"Siemens 5SJ4216-7HG41 2-Pole MCB, C-Curve, 10 kA","metaDescription":"Siemens SENTRON 5SJ4216-7HG41 2-pole miniature circuit breaker, C-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2). Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SJ4216-7HG41","Height":"110 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 240 V 14kA, 2-pole, C, 16A, D=70 mm according to UL 489","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"on standard mounting rail","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breakers","protection class IP":"IP20, with connected conductors, IP 40 in the handle range","Overvoltage Category":"3","Tunnel Terminals Top":"No","Vibration Resistance":"50 m/s² at 25 to 150Hz and 60m/s² at 35Hz (4sec)","Combined Terminal Top":"Yes","Design Of The Product":"Miniature circuit-breaker 5SJ4","Product Function Note":"Terminal tightening torque for Cu, 60/75°C; 3.5Nm/31lb.in","Tunnel Terminals Bottom":"No","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","at DC rated value maximum":"60 V","Neutral Conductor Switching":"No","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"10 kA","Ambient Temperature During Operation":"max. 95% humidity","Supply Voltage Frequency Rated Value":"50 Hz","according to IEC 60947-2 rated value":"15 kA","installation environment regarding EMC":"Suitable for environment B (immunity to interference not applicable)","insulation voltage (Ui) at AC rated value":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"±1 mm at 5 to 25 Hz; 50 m/s² at 25 to 150 Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Tightening Torque With Screw-Type Terminals Maximum":"3.5 N·m","power loss [W] for rated value of the current at AC in hot operating state per pole":"2.2 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$74.93","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/17c9d522ce486748fbba022989d30334.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=434500&mlfb=5SJ4216-7HG41"},"ai":{"faq":[{"question":"Does the 5SJ4216-7HG41 accept a busbar comb?","answer":"Yes, the combined terminal design at both top and bottom accepts standard SENTRON pin-type or fork-type busbars without modification. The terminal torque spec is 3.5 Nm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SJ4216-7HG41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SJ4216-7HG41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}